{"product_id":"ge-fanuc-is220ptcch2bb-mark-vie-thermocouple-input-pack","title":"GE Fanuc IS220PTCCH2BB Mark VIe Thermocouple Input Pack","description":"\u003cp\u003eConfigured for precise temperature monitoring in Mark VIe turbine control platforms, the \u003cstrong\u003eGE Fanuc IS220PTCCH2BB\u003c\/strong\u003e (\u003cstrong\u003eIS220PTCC\u003c\/strong\u003e Thermocouple Input Pack) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS220PTCCH2BB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e241 mm x 194 mm x 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC or 125 VDC nominal supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Inputs\u003c\/td\u003e\n\u003ctd\u003e12 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Thermocouple Types\u003c\/td\u003e\n\u003ctd\u003eE, J, K, S, T, B, N, R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Conversion Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Control Modes\u003c\/td\u003e\n\u003ctd\u003eSimplex, Dual, TMR (Triple Modular Redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Safety Rating\u003c\/td\u003e\n\u003ctd\u003eSIL 2 \/ SIL 3 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication Velocity \u0026amp; Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe physical Layer 1\/2 hardware architecture features full firmware flash compatibility validation, preventing packet drop during high-density I\/O traffic scaling and broadcast storm events. Fast Ethernet transceivers support auto-negotiation and auto-MDI\/MDIX crossover detection across all network channels, maintaining optimized backplane bus communication velocity and sub-microsecond latency execution across Profinet \/ EtherNet\/IP deterministic networks and dedicated IONet dual Ethernet topologies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS220PTCCH2BB support Triple Modular Redundant (TMR) mode execution without hardware modification?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module native architecture allows deployment in Simplex, Dual, or TMR configurations. Redundancy modes are assigned electronically via the Mark VIe control software framework without requiring physical jumpers.\u003c\/p\u003e\n\u003cp\u003eQ: How is high-resolution analog conversion managed across all 12 input channels?\u003c\/p\u003e\n\u003cp\u003eA: Each of the 12 thermocouple input channels utilizes an onboard 16-bit A\/D converter, providing high-density signal digitizing across supported sensor curves (E, J, K, S, T, B, N, R).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the assembly vertically on a DIN rail or panel frame within an enclosure providing appropriate ingress protection.\u003c\/li\u003e\n\u003cli\u003eConnect all protective earthing leads to the enclosure grounding bar using low-impedance copper conductors prior to energizing the unit.\u003c\/li\u003e\n\u003cli\u003eMaintain dedicated wiring trays for all 12 thermocouple input channels to isolate millivolt-level signal lines from AC power cables.\u003c\/li\u003e\n\u003cli\u003eEnsure a minimum of 5 full thread engagements on all NPT conduit fittings entering hazardous area enclosure boundaries.\u003c\/li\u003e\n\u003cli\u003eVerify that supply voltages remain strictly within specified limits of 24 VDC or 125 VDC during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":48749989888190,"sku":"IS220PTCCH2BB","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/IS210MACCH2A_1200x1200_f6a5b399-1b28-4b1d-845e-c738a6f05cfb.jpg?v=1787023706","url":"https:\/\/www.autooiltech.com\/products\/ge-fanuc-is220ptcch2bb-mark-vie-thermocouple-input-pack","provider":"AutoOilTech Limited","version":"1.0","type":"link"}