{"product_id":"ge-fanuc-is200trlys1bgg-relay-terminal-board","title":"GE Fanuc IS200TRLYS1BGG Relay Terminal Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200TRLYS1BGG\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200TRLYS1BGG\u003c\/strong\u003e Relay Terminal Board, serves as a discrete I\/O barrier-type board with plug-in magnetic relays for diagnostics of coil current within Mark VI Speedtronic turbine control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eIS200TRLYS1BGG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eGE Fanuc (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eRectangular PCB form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eRelay Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eRelay Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003ePlug-in magnetic relays, Form C contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Blocks\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e2 strips with numbered screw connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e4 D-shell connectors, 3 three-pin plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAdditional Components\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eIntegrated circuits, variable resistors, fuses, capacitors, diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IS200TRLYS1BGG integrates into the Mark VI backplane with firmware flash compatibility across discrete I\/O modules. Backplane bus communication ensures deterministic relay actuation and diagnostic feedback. I\/O density scaling is achieved by distributing coil current diagnostics across multiple TRLY boards. Compatibility is maintained with related modules such as TBCI, DTCI, TICI, and DRLY, allowing flexible integration into turbine control architectures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IS200TRLYS1BGG provide diagnostics for contact voltage? A: No. This version is specific to coil current diagnostics. For contact voltage diagnostics, use a TRLY board ending in H1C.\u003c\/p\u003e\n\u003cp\u003eQ: Does the board support partial power protection? A: Yes. In certain configurations, it can provide limited power protection when connected to 120\/240 VAC sources.\u003c\/p\u003e\n\u003cp\u003eQ: Are the relays replaceable? A: Yes. The plug-in magnetic relays are designed for replacement and maintenance without full board substitution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure proper seating of plug-in relays; verify Form C contact alignment.\u003c\/li\u003e\n\u003cli\u003eTerminate wiring at numbered screw terminals for traceability.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between diagnostic coil current circuits and high-voltage sources.\u003c\/li\u003e\n\u003cli\u003eSecure D-shell connectors with full mechanical engagement to prevent intermittent signals.\u003c\/li\u003e\n\u003cli\u003eVerify fuse integrity before commissioning to avoid relay malfunction.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electricneral Electric","offers":[{"title":"Default Title","offer_id":47634982568126,"sku":"IS200TRLYS1BGG","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is200trlyh1bgg-relay-output-terminal-board-1qariiqe1t0.png?v=1759044089","url":"https:\/\/www.autooiltech.com\/products\/ge-fanuc-is200trlys1bgg-relay-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}