{"product_id":"ge-fanuc-ic694mdl340-120-vac-discrete-output-module","title":"GE Fanuc IC694MDL340 120 VAC Discrete Output Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eIC694MDL340\u003c\/strong\u003e is a 16‑point AC output module engineered for the PACSystems RX3i platform. It delivers reliable 120 VAC discrete output control for industrial loads such as contactors, relays, indicator lamps, and other AC‑driven devices. Outputs are arranged in two isolated groups of eight channels, allowing flexible field wiring and improved fault isolation. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"text-lg-strong pb-1 [\u0026amp;:not(:first-child)]:pt-3.5\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eModel \u003c\/span\u003e\u003cspan\u003eNumber\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIC694MDL340\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eProduct \u003c\/span\u003e\u003cspan\u003eType\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eAC \u003c\/span\u003e\u003cspan\u003eDiscrete \u003c\/span\u003e\u003cspan\u003eOutput \u003c\/span\u003e\u003cspan\u003eModule\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eOutput \u003c\/span\u003e\u003cspan\u003ePoints\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e16 \u003c\/span\u003e\u003cspan\u003e(2 \u003c\/span\u003e\u003cspan\u003egroups \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003e8)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eOutput \u003c\/span\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e85–132 VAC, \u003c\/span\u003e\u003cspan\u003enominal \u003c\/span\u003e\u003cspan\u003e120 VAC\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eOutput \u003c\/span\u003e\u003cspan\u003eCurrent\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e0.5 A \u003c\/span\u003e\u003cspan\u003eper \u003c\/span\u003e\u003cspan\u003epoint; \u003c\/span\u003e\u003cspan\u003e3 A \u003c\/span\u003e\u003cspan\u003eper \u003c\/span\u003e\u003cspan\u003egroup\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eInrush \u003c\/span\u003e\u003cspan\u003eCurrent\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e20 A \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003e1 \u003c\/span\u003e\u003cspan\u003ecycle\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e250 VAC \u003c\/span\u003e\u003cspan\u003econtinuous; \u003c\/span\u003e\u003cspan\u003e1500 VAC \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003e1 \u003c\/span\u003e\u003cspan\u003eminute\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eUL, \u003c\/span\u003e\u003cspan\u003eCE, \u003c\/span\u003e\u003cspan\u003eATEX, \u003c\/span\u003e\u003cspan\u003eMarine \u003c\/span\u003e\u003cspan\u003eapprovals\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eRX3i \u003c\/span\u003e\u003cspan\u003erack‑based \u003c\/span\u003e\u003cspan\u003einstallation\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e34 \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e145 \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e140 mm \u003c\/span\u003e\u003cspan\u003e(module \u003c\/span\u003e\u003cspan\u003efamily \u003c\/span\u003e\u003cspan\u003ereference)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTypical \u003c\/span\u003e\u003cspan\u003eLoads\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eRelays, \u003c\/span\u003e\u003cspan\u003econtactors, \u003c\/span\u003e\u003cspan\u003eAC \u003c\/span\u003e\u003cspan\u003eindicators\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"text-lg-strong pb-1 [\u0026amp;:not(:first-child)]:pt-3.5\"\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eIC694MDL340\u003c\/strong\u003e is well‑suited for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC motor starters and relay control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcess equipment requiring 120 VAC switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh‑inrush inductive loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed I\/O in RX3i‑based automation systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial machinery modernization and expansion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the module handle inductive loads?\u003c\/strong\u003e Yes. It supports up to 20 A inrush for one cycle, making it suitable for relays and solenoids. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many isolated groups does it have?\u003c\/strong\u003e Two groups of eight channels, each with independent field power. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is it compatible with all RX3i racks?\u003c\/strong\u003e Yes. There are no backplane restrictions for this module.\u003c\/span\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":46180981211326,"sku":"IC694MDL340","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/ge-fanuc-ic694mdl930-voltage-output-module-lpyb1g0i2nl_17907e03-4604-4721-9837-f5efcf84f832.png?v=1758877324","url":"https:\/\/www.autooiltech.com\/products\/ge-fanuc-ic694mdl340-120-vac-discrete-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}