{"product_id":"ge-fanuc-12a0-0102-a1-ur-series-bus-board","title":"GE Fanuc 12A0-0102-A1 UR Series Bus Board","description":"\u003cp\u003eConfigured for high-speed data transfer and internal bus communication in GE Universal Relay (UR) Series networks, the \u003cstrong\u003eGE Fanuc 12A0-0102-A1\u003c\/strong\u003e (\u003cstrong\u003e12A0-0102-A1\u003c\/strong\u003e UR Series Bus Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCore Function Architecture\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eArchitectural Application\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e12A0-0102-A1\u003c\/td\u003e\n\u003ctd\u003eStandard Internal Backplane Bus Board\u003c\/td\u003e\n\u003ctd\u003eGE Universal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12A0-0102-...\u003c\/td\u003e\n\u003ctd\u003eBase Variant Family\u003c\/td\u003e\n\u003ctd\u003eMultilin Protective Relay Frameworks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e12A0-0102-A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e250.0 mm x 120.0 mm x 20.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.0 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eInternal high-speed backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE UR Series, UR200 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 12A0-0102-A1 bus board utilizes robust backplane bus communication velocity architecture to manage data exchange rates across modular UR relay subsystems. It maintains low-latency signal distribution between plug-in processing modules and power units while withstanding severe industrial electromagnetic interference. Furthermore, internal firmware flash compatibility ensures that onboard bus controller logic can be updated via authorized management tools without requiring hardware replacement.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the 12A0-0102-A1 board within the UR relay architecture?\u003c\/p\u003e\n\u003cp\u003eA: It serves as the internal backplane bus board, providing high-speed data communication and power distribution links between the various plug-in modules of the GE Universal Relay system.\u003c\/p\u003e\n\u003cp\u003eQ: What nominal voltage does the bus board require for internal system operation?\u003c\/p\u003e\n\u003cp\u003eA: The board operates on a regulated DC power input of 24 VDC supplied by the main power supply module of the relay chassis.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that all external AC and DC power sources to the UR relay chassis are completely disconnected before installing or replacing the 12A0-0102-A1 bus board. Handle the printed circuit board by its edges while wearing an ESD wrist strap to prevent electrostatic discharge damage to sensitive components. Slide the board securely into its designated backplane mounting slots, ensuring all edge connectors are fully seated before fastening securing screws.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48221193666750,"sku":"12A0-0102-A1","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/12A0-0102-A1_2.png?v=1785287991","url":"https:\/\/www.autooiltech.com\/products\/ge-fanuc-12a0-0102-a1-ur-series-bus-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}