{"product_id":"ge-f35e00hchf8fh6gm8fp6huxxwxx-multiple-feeder-protection-module","title":"GE F35E00HCHF8FH6GM8FP6HUXXWXX Multiple Feeder Protection Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc Multilin F35E00HCHF8FH6GM8FP6HUXXWXX\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF35\u003c\/strong\u003e Multiple Feeder Protection Module, operates as a dedicated hardware component for multi-circuit protection, programmatic reclosing management, and high-density waveform metering within modular substation engineering architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF35E00HCHF8FH6GM8FP6HUXXWXX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e13.20 lbs (5.99 kg) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 4U high-density rack-mounted platform architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C (-40 to 185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Compliance\u003c\/td\u003e\n\u003ctd\u003e5% to 95% relative humidity (non-condensing margins)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Zones\u003c\/td\u003e\n\u003ctd\u003e3 Mho Distance zones (Phase\/Ground), 3 Quadrilateral Distance zones (Phase\/Ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Scheme\u003c\/td\u003e\n\u003ctd\u003e3-pole tripping sequence optimization for single breaker systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePickup Scaling Range\u003c\/td\u003e\n\u003ctd\u003e0.004 to 3.000 pu calibrated in 0.001 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDropout Threshold\u003c\/td\u003e\n\u003ctd\u003e97% to 98% of the active pickup configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlgorithmic Operate Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;30 ms at 1.1x pickup limits (measured on 60 Hz base loops)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Accuracy Margin\u003c\/td\u003e\n\u003ctd\u003e±3% or ±20 ms (whichever baseline parameter evaluates greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Networks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity:\u003c\/strong\u003e The hardware platform routes raw digital samples from the analog card slots across a high-speed parallel internal bus structure. This framework ensures that calculated distance protection matrices update in real time, executing fault clearance triggers within fixed millisecond clock intervals to maximize power line stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling:\u003c\/strong\u003e The modular frame accepts distinct input topologies including completely independent current\/voltage paths, independent current\/common voltage arrays, or dedicated current-only links. This variable density packs multiple distinct feeder protection sectors into a unified 4U chassis, dropping external hardware count.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility:\u003c\/strong\u003e Core tripping equations, reclosing logic maps, and network protocol dictionaries reside in non-volatile flash sectors. The hardware firmware version must correlate exactly with the active engineering software platform build to prevent operational configuration blocks during runtime modifications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47616279150782,"sku":"F35E00HCHF8FH6GM8FP6HUXXWXX","price":620.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-05_17-47-51_52fb1dec-0d8f-4774-af5c-a5b1c25eb8f5.png?v=1780995176","url":"https:\/\/www.autooiltech.com\/products\/ge-f35e00hchf8fh6gm8fp6huxxwxx-multiple-feeder-protection-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}