{"product_id":"ge-ds200tcrag1acc-relay-output-board","title":"GE DS200TCRAG1ACC Relay Output Board","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric DS200TCRAG1ACC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200TCRAG1\u003c\/strong\u003e Relay Output Board, operates as a dedicated hardware component for high-current discrete command execution and actuator interface management within Mark V Speedtronic turbine control architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eRevision\/Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200TCRAG1\u003c\/td\u003e\n\u003ctd\u003eBase Relay Output Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eFunctional Revision 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eFunctional Revision 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eArtwork Revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCRAG1ACC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.65 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V PCB footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial turbine enclosure range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control System Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane bus communication velocity:\u003c\/strong\u003e The board interfaces with the Mark V backplane to receive logic commands for relay actuation. This is mandatory for executing turbine protective trips and auxiliary start\/stop sequences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP deterministic networks:\u003c\/strong\u003e The board architecture is optimized for the proprietary Speedtronic backplane, providing deterministic timing for relay state transitions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O density scaling:\u003c\/strong\u003e The board supports high-capacity relay output channels, facilitating robust discrete control for turbine-driven machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware flash compatibility:\u003c\/strong\u003e Operational parameters must be aligned with system firmware requirements. Verification of the hardware revision and software compatibility is mandatory to ensure correct relay logic execution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DS200TCRAG1ACC provide mechanical isolation for output loads?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The board utilizes onboard relays to provide galvanic isolation between the low-voltage control backplane and the high-current field loads.\u003c\/p\u003e\n\u003cp\u003eQ: Is this relay board compatible with standard Mark V relay control cards?\u003c\/p\u003e\n\u003cp\u003eA: Yes. It is designed as a direct component within the Mark V relay output architecture. Verification of existing part numbers and hardware revision levels is required for substitution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the board into the designated Mark V rack slot. Given the mass of the relay assembly, ensure the board is fully supported by the rack guides to prevent connector stress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the board chassis to the rack earth bus. This is mandatory to prevent relay switching noise from impacting adjacent control circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field-side actuator loads to the relay terminals. Adhere to specified voltage and current limits to prevent relay contact degradation. Maintain 150 mm separation from low-voltage signal wiring to prevent electromagnetic coupling from switched inductive loads.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48124836315326,"sku":"DS200TCRAG1ACC","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-10_09-27-51_c3c80f2c-34f4-4d2b-a54f-39e5212f8e82.png?v=1783655658","url":"https:\/\/www.autooiltech.com\/products\/ge-ds200tcrag1acc-relay-output-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}