{"product_id":"ge-ds200tbqcg1abb-analog-input-milliamp-i-o-termination-module","title":"GE DS200TBQCG1ABB Analog Input Milliamp I\/O Termination Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE DS200TBQCG1ABB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTBQC\u003c\/strong\u003e Analog Input Milliamp I\/O Termination Module, provides current signal interfacing for Mark V Speedtronic turbine control systems. It connects 4-20 mA inputs and LVDT\/R position inputs to the TCQA board, with configurable output ranges via hardware jumpers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e DS200TBQCG1ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE General Electric\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark V LM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Input Milliamp I\/O Termination Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommon Mode Voltage Range:\u003c\/strong\u003e +5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Lead Resistance:\u003c\/strong\u003e 15 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Output Current:\u003c\/strong\u003e 0-20 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50 or 60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30 to 55 deg C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSize:\u003c\/strong\u003e 8.26 cm high x 4.18 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 2 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e United States\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManual:\u003c\/strong\u003e GEI-100222\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAvailability:\u003c\/strong\u003e In Stock\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eI\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe DS200TBQCG1ABB supports configurable output ranges of 20 mA or 200 mA maximum current, selectable via hardware jumpers. This flexibility allows adaptation to varying sensor and actuator requirements. Analog signals are conditioned and routed to TCQA boards, ensuring deterministic conversion cycles across the Mark V LM backplane bus.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ: How are the output ranges configured? A: Hardware jumpers on the TBQC terminal board allow selection between 20 mA and 200 mA maximum current outputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: What types of signals can be connected? A: The board interfaces with 4-20 mA analog inputs and LVDT\/R position inputs, routed to TCQA boards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Does the TBQC operate independently from the processor? A: Yes. Dynamic discharge circuits monitor DC link voltage and execute control actions independently of the control processor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure proper seating in location nine of the Mark V LM rack with full connector engagement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintain shielded cable grounding at a single point to suppress EMI.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoute analog signal wiring separately from high-voltage lines to minimize interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify jumper settings for correct output range before energizing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eObserve ambient temperature limits (-30 to 55 deg C) during installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45446741754046,"sku":"DS200TBQCG1ABB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-ds200tbqdg1aff-rst-extension-terminal-board-od0wicadfwj.png?v=1759132039","url":"https:\/\/www.autooiltech.com\/products\/ge-ds200tbqcg1abb-analog-input-milliamp-i-o-termination-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}