{"product_id":"ge-ds200tbqag1abb-thermocouple-input-terminal-board","title":"GE DS200TBQAG1ABB Thermocouple Input Terminal Board","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric DS200TBQAG1ABB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200TBQAG1\u003c\/strong\u003e Termination Board, operates as a dedicated hardware component for thermocouple signal acquisition and field-level terminal management within Mark V Speedtronic turbine control architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eRevision\/Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200TBQAG1\u003c\/td\u003e\n\u003ctd\u003eBase Thermocouple Input Termination Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eFunctional Revision 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eFunctional Revision 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eArtwork Revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TBQAG1ABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V PCB footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial turbine enclosure range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control System Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane bus communication velocity:\u003c\/strong\u003e The board facilitates high-speed analog signal exchange between field-level thermocouple sensors and the Mark V central processor. This is mandatory for maintaining the timing precision required for turbine thermal monitoring and protective interlocking logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP deterministic networks:\u003c\/strong\u003e The board architecture is engineered to maintain deterministic signal states consistent with the proprietary Speedtronic backplane communication cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O density scaling:\u003c\/strong\u003e The PCB supports high-density thermocouple connectivity, allowing for efficient management of multiple temperature measurement channels within a single rack assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware flash compatibility:\u003c\/strong\u003e The configuration of the board must be reconciled with the system control software requirements. Verification of the hardware revision and existing system firmware is mandatory to prevent control logic execution errors during integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the DS200TBQAG1ABB compatible with standard thermocouple types?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The board is designed to interface with industrial standard thermocouples. Precise signal linearization and cold junction compensation are managed through the system configuration software associated with the specific Mark V control application.\u003c\/p\u003e\n\u003cp\u003eQ: Can this board be used as a direct substitute for the DS200TBQAG1 base model?\u003c\/p\u003e\n\u003cp\u003eA: The DS200TBQAG1ABB is a revised version of the base model. Substitution is generally supported, but verification of the hardware revision level and existing terminal mapping is mandatory to ensure system compatibility and process safety.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the PCB securely within the Mark V control rack. Ensure all edge connectors engage fully with the backplane; incomplete engagement can lead to signal instability or intermittent thermocouple readings in critical thermal loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e The assembly must be properly bonded to the rack chassis to maintain a stable reference potential. Effective grounding is mandatory to mitigate high-frequency EMI common in turbine enclosure environments and to protect the board from ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate field-level thermocouple wires into the designated terminal blocks. Maintain consistent polarity to ensure accurate cold junction reference. Ensure thermocouple wiring is shielded and segregated from high-power AC lines by a minimum of 150 mm to prevent inductive noise injection into the sensitive mV-level signals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48124754002110,"sku":"DS200TBQAG1ABB","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-10_09-26-50.png?v=1783655614","url":"https:\/\/www.autooiltech.com\/products\/ge-ds200tbqag1abb-thermocouple-input-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}