{"product_id":"ge-ds200sdcig1ahb-power-supply-boards","title":"GE DS200SDCIG1AHB Power Supply Boards","description":"\u003cp\u003eThe \u003cstrong\u003eGE DS200SDCIG1AHB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200SDCIG1\u003c\/strong\u003e DC Power Supply and Instrumentation Board, operates as a dedicated hardware component for power regulation and instrumentation interfacing within Mark V turbine control systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \u0026amp; Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200\u003c\/td\u003e\n\u003ctd\u003eSeries Tag\u003c\/td\u003e\n\u003ctd\u003eMark V Series assembly and domestic original manufacture location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDCI\u003c\/td\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eDC Power Supply and Instrumentation Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG1\u003c\/td\u003e\n\u003ctd\u003eProduct Grouping\u003c\/td\u003e\n\u003ctd\u003eGroup one Mark V Series architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1A\u003c\/td\u003e\n\u003ctd\u003eFunctional Revision 1\u003c\/td\u003e\n\u003ctd\u003eInitial primary functional revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003eFunctional Revision 2\u003c\/td\u003e\n\u003ctd\u003eSecondary functional hardware revision level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eArtwork Revision\u003c\/td\u003e\n\u003ctd\u003eBoard layout and trace routing artwork version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200SDCIG1AHB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V \/ DC2000 Drive Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.18 kg (2.61 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V PCB form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent internal logic load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eNormal coating style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection\u003c\/td\u003e\n\u003ctd\u003eInternal FU5 fuse for 10 A field and MOV assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Backplane Communication Velocity\u003c\/h3\u003e\n\u003cp\u003eThe board integrates within industrial control frameworks utilizing robust backplane communication velocity links, ensuring synchronized data exchange across turbine management nodes. Profinet and EtherNet\/IP deterministic network integration protocols are supported through dedicated interface pathways, permitting real-time telemetry processing and precise drive parameter updates. I\/O density scaling and firmware flash compatibility features enable seamless configuration adjustments during system maintenance cycles without compromising loop update rates.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the specific function of fuse \"FU5\" on the DS200SDCIG1AHB board?\u003c\/p\u003e\n\u003cp\u003eA: Fuse \"FU5\" serves as the internal protection element dedicated to the 10 A field and MOV assembly circuits.\u003c\/p\u003e\n\u003cp\u003eQ: Where can jumper definitions and configuration details be located for this board?\u003c\/p\u003e\n\u003cp\u003eA: Jumper configurations, descriptions, and revision details are explicitly outlined in Manual GEI-100173, Table 2.\u003c\/p\u003e\n\u003cp\u003eQ: Does the board support live hot-swapping inside an energized Mark V rack?\u003c\/p\u003e\n\u003cp\u003eA: No. Power must be completely isolated and verified absent using a multimeter before handling or replacing the board to prevent electrical shock and hardware damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eKeep the board inside its static protective bag until immediate installation within the drive cabinet enclosure.\u003c\/li\u003e\n\u003cli\u003eEnsure all power sources to the Mark V core and associated drive circuits are locked out and tested for zero energy state.\u003c\/li\u003e\n\u003cli\u003eAlign the board carefully with the card guide slots and press firmly to seat the edge connector fully into the backplane bus.\u003c\/li\u003e\n\u003cli\u003eSecure any retaining screws and verify jumper settings against manual GEI-100173 prior to system re-energization.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48179975946430,"sku":"DS200SDCIG1AHB","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-10_09-07-57_cb57c0d1-67af-4c53-a665-4214d4e76d40.png?v=1784625271","url":"https:\/\/www.autooiltech.com\/products\/ge-ds200sdcig1ahb-power-supply-boards","provider":"AutoOilTech Limited","version":"1.0","type":"link"}