{"product_id":"ge-ds200ptctg1baa-signal-conditioner-card","title":"GE DS200PTCTG1BAA Signal Conditioner Card","description":"\u003cp\u003eConfigured for signal scaling and isolation in Mark V Speedtronic systems, the \u003cstrong\u003eGE DS200PTCTG1BAA\u003c\/strong\u003e (\u003cstrong\u003eDS200PTCTG1\u003c\/strong\u003e Signal Conditioner Card) provides direct physical\/electrical execution of Potential Transformer (PT) and Current Transformer (CT) signal processing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200PTCTG1BAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard PCB assembly weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMark V standard form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial Mark V standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-specific load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e72 signal wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Configuration\u003c\/td\u003e\n\u003ctd\u003e1 x 50-pin, JKK connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC and Industrial Control Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDS200PTCTG1BAA\u003c\/strong\u003e functions as an analog front-end for the Mark V architecture, responsible for conditioning high-voltage inputs for control-level consumption. It integrates with the TCCB board via the JKK interface to support secondary isolation. The module performs hardware-based rectification and voltage limiting using integrated circuits and passive components; it requires no firmware flash compatibility or software-defined communication velocity licensing, as its operation is determined by the physical circuit topology and host backplane signal state.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Are the three functional revisions of this module backwards-compatible?\u003c\/p\u003e\n\u003cp\u003eA: No. Only the first two revisions (B and A-rated) are considered backwards-compatible. The third revision, relating to artwork configuration, does not maintain full functional equivalence with earlier versions.\u003c\/p\u003e\n\u003cp\u003eQ: Are specific mounting provisions integrated into the PCB?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The board features factory-drilled installation holes ringed with insulation material to facilitate secure mounting and prevent short-circuiting against the rack chassis.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Segregation\u003c\/strong\u003e: To prevent electromagnetic interference (EMI), route high-voltage power cables separately from low-voltage signal cables. If parallel routing is unavoidable, minimize the parallel run length. Where signal and power cables must intersect, ensure they cross at a 90 degree angle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Requirements\u003c\/strong\u003e: Utilize shielded cabling for signal input\/output paths to minimize noise pickup. Terminate shields according to the Mark V system ground specification to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Termination\u003c\/strong\u003e: The board includes a 72-position terminal block. Ensure all conductors (OUT1, OUT2, COM1, COM2, P15, SO21, L23) are properly seated and torqued to prevent intermittent connection or signal instability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protocol\u003c\/strong\u003e: The PCB contains sensitive integrated circuits. Use a grounded wrist strap and anti-static surface during installation and maintenance to prevent damage from electrostatic discharge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Integrity\u003c\/strong\u003e: Verify that the board is correctly aligned with the rack mounting standoffs. Use all provided fasteners to ensure the PCB remains flat and stable during turbine operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48177217568958,"sku":"DS200PTCTG1BAA","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-20_09-27-49_782e68dc-856b-4c6a-b375-3036d31d9697.png?v=1784517269","url":"https:\/\/www.autooiltech.com\/products\/ge-ds200ptctg1baa-signal-conditioner-card","provider":"AutoOilTech Limited","version":"1.0","type":"link"}