{"product_id":"ge-ds200lrpag1a-line-protection-card","title":"GE DS200LRPAG1A Line Protection Card","description":"\u003cp\u003eConfigured for line protection tasks in Mark V turbine control systems, the \u003cstrong\u003eGE DS200LRPAG1A\u003c\/strong\u003e (\u003cstrong\u003eDS200LRPA\u003c\/strong\u003e Line Protection Card) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe functional product number designates specific hardware attributes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDS200\u003c\/strong\u003e: Indicates the Mark V Series assembly and domestic original manufacture location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLRPA\u003c\/strong\u003e: Denotes the functional product abbreviation for the line protection card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup 1\u003c\/strong\u003e: Specifies the Mark V Series product grouping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Represents the primary functional product revision (A-rated).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200LRPAG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eDomestic Original Manufacture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard PCB Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eRectangular Form Factor with Corner Drill Holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Mark V Rating (-20 deg C to +65 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDerived from Mark V Rack Rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Function\u003c\/td\u003e\n\u003ctd\u003eLine Protection and Voltage Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility \u0026amp; Backplane Communication\u003c\/h3\u003e\n\u003cp\u003eIntegrated within the Speedtronic Mark V control platform, the \u003cstrong\u003eDS200LRPAG1A\u003c\/strong\u003e coordinates signal management and protective circuit functions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility:\u003c\/strong\u003e Requires matched system software configurations to validate operational parameters and execute diagnostic routines across the control network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity:\u003c\/strong\u003e Processes high-speed data exchanges across system rails to maintain real-time monitoring efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling:\u003c\/strong\u003e Interfaces directly with system sensors and voltage regulation components to support protective line switching.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the DS200LRPAG1A mount in the automated drive assembly?\u003c\/p\u003e\n\u003cp\u003eA: The board mounts using factory-drilled installation holes in its base circuit board, as it does not include a metal faceplate for VME rack mounting.\u003c\/p\u003e\n\u003cp\u003eQ: Is the DS200LRPAG1A circuit board considered fragile?\u003c\/p\u003e\n\u003cp\u003eA: While it requires careful handling like any PCB, it is not categorized as overly fragile since several hardware components are protected within basic enclosures or mounting structures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Ensure all rack power supplies are completely de-energized before handling or installing the circuit board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge Protection:\u003c\/strong\u003e Utilize a properly grounded wrist strap connected to the designated cabinet earth point to safeguard solid-state components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Align the board using the corner and edge drill holes, securing it with appropriate standoffs or screws without over-tightening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Seating:\u003c\/strong\u003e Verify that vertical female cable connectors and terminal strips are firmly engaged to prevent intermittent signal transmission.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48205900972222,"sku":"DS200LRPAG1A","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/DS200XDSAG1A_90637236-10cf-45fb-86f5-219c605e226f.png?v=1785116137","url":"https:\/\/www.autooiltech.com\/products\/ge-ds200lrpag1a-line-protection-card","provider":"AutoOilTech Limited","version":"1.0","type":"link"}