{"product_id":"ge-d25-0158-000001-digital-input-output-module","title":"GE D25-0158-000001 Digital Input\/Output Module","description":"\u003cp\u003eConfigured for high-density discrete signal polling and relay control execution within substation automation networks, the \u003cstrong\u003eGE Fanuc D25-0158-000001\u003c\/strong\u003e (\u003cstrong\u003eD25-0158-000001\u003c\/strong\u003e Digital Input\/Output Module) provides direct physical\/electrical execution. It locks input transitions and drives output coils natively at the terminal tier to track field contacts parallel to master control network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eD25-0158-000001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ GE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCanada \/ United States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard multi-channel I\/O card package parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19-inch rack slot sub-assembly chassis parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eCalibrated for standard utility substation environmental limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDissipation limits capped at 0.5 W maximum per active input path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003eUp to 96 channels (Optically isolated to 5000 Vrms, 32-input cards)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e12 VDC, 24 VDC, 48 VDC, 120 VDC, 250 VDC +\/- 20% bipolar configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetting Voltage\u003c\/td\u003e\n\u003ctd\u003eIntegrated on-board wetting supply execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e16 or 32 relay channels (1 Form A configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Limits\u003c\/td\u003e\n\u003ctd\u003e2 A continuous; 60 W DC \/ 125 VA AC maximum resistive load bounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Timing\u003c\/td\u003e\n\u003ctd\u003e5 ms operational engagement time \/ 5 ms release cycle window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity Licences and Processing Logic:\u003c\/strong\u003e Onboard processing sub-circuits run localized, three-level programmable software debouncing and chatter filters. Because discrete signal cleanup and 1 ms Sequence of Events (SOE) time-tagging happen within local logic chips, processing 96 high-frequency input transitions does not limit the backplane bus communication velocity properties assigned to master CPU networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks Mapping:\u003c\/strong\u003e Active state registers, pulse accumulator values, and relay contact states are saved directly into internal memory blocks. These metrics map to supervisory Profinet \/ EtherNet\/IP deterministic networks via external network drops, giving upstream SCADA architectures fast status updates without communication delays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Relay Control Optimization:\u003c\/strong\u003e Combining 96 optically isolated inputs and up to 32 relay outputs with built-in select-check-before-execute security maximizes local configurations. This layout expands overall local I\/O density scaling capabilities inside breaker cabinets, allowing direct trip\/close commands and status tracking without needing extra interposing cards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What technical tracking behavior manifests if an adjacent output channel experiences a major voltage surge during a breaker trip?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on physical isolation paths to manage faults. The design provides 300 VDC isolation between adjacent channels on compression terminal blocks (100 VDC for DB-25 setups) and 1500 VAC from coil to contact, which stops high-voltage spikes from bleeding into the backplane logic runs.\u003c\/p\u003e\n\u003cp\u003eQ: Can the D25-0158-000001 module be pulled from the 19-inch rack assembly while the primary control loop outputs are energized?\u003c\/p\u003e\n\u003cp\u003eA: No. The backplane edge contacts do not have staggered pin configurations optimized for live hot-swapping. Unplugging the card under active load can create inductive arcs across the logic pins, risking hardware failure and memory faults on the tracking network.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47800180146366,"sku":"D25-0158-000001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-26_09-50-15_70c9b4a5-5ed0-44eb-8355-d702cb8146d3.png?v=1782442035","url":"https:\/\/www.autooiltech.com\/products\/ge-d25-0158-000001-digital-input-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}