{"product_id":"ge-369-hi-0-0-0-0-0-e-motor-protection-relay","title":"GE 369-HI-0-0-0-0-0-E Motor Protection Relay","description":"\u003cp\u003eThe \u003cstrong\u003eGE Multilin 369-HI-0-0-0-0-0-E\u003c\/strong\u003e, operating as part of the \u003cstrong\u003e369\u003c\/strong\u003e Motor Management Series, serves as the primary \u003cstrong\u003e369\u003c\/strong\u003e Motor Protection Relay utilized to execute complete monitoring, advanced diagnostics, and thermal overload protection for industrial three-phase motors.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e369-HI-0-0-0-0-0-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e369 Motor Management System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power Input\u003c\/td\u003e\n\u003ctd\u003e50 to 300 VDC \/ 60 to 265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-In RTD Inputs\u003c\/td\u003e\n\u003ctd\u003e0 (Absent based on product number coding)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eEnhanced LED-backlit display window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics Subsystem\u003c\/td\u003e\n\u003ctd\u003eEnhanced local diagnostic tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e10 Labeled front-panel LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Interface\u003c\/td\u003e\n\u003ctd\u003e12 Labeled front-panel push buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eHarsh Environment Hardware Package (Trailing E-suffix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModification Status\u003c\/td\u003e\n\u003ctd\u003eStandard configuration (No modifications applied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Motor Infrastructure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Stage Execution\u003c\/strong\u003e The universal HI power stage safely receives an extensive electrical profile spanning 50 to 300 VDC or 60 to 265 VAC. This internal power design ensures continuous protection monitoring and maintains logical instruction processing during acute industrial power grid transients or battery bank sag events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced User Interface and Diagnostics\u003c\/strong\u003e The unit features an enhanced front-panel design crafted from rugged plastic material with a two-tone layout. Ten labeled LED indicators provide immediate status tracking while twelve dedicated operator push buttons enable direct interaction. The enhanced diagnostics engine continuously logs fault parameters and motor metrics to the high-visibility LED-backlit display window.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 369-HI-0-0-0-0-0-E include direct terminal connections for stator RTD sensing elements?\u003c\/p\u003e\n\u003cp\u003eA: No. The second digit \"0\" within the 369-HI-0-0-0-0-0-E model string confirms the absolute absence of the 12 typical built-in Resistance Temperature Detector (RTD) thermal inputs. For applications demanding direct bearing or stator thermal tracking, external remote RTD monitoring modules must interface with the relay via communication loops.\u003c\/p\u003e\n\u003cp\u003eQ: Is this specific module configuration protected against aggressive plant atmospheres?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The trailing \"E\" digit explicitly confirms that this hardware assembly includes the factory Harsh Environment option package. The internal circuit boards feature advanced conformal coatings engineered to resist moisture, airborne chemical contaminants, and particulate corrosion common to harsh industrial operating sectors.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47618382790846,"sku":"369-HI-0-0-0-0-0-E","price":620.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-08_09-17-41_ecbf77cf-4861-4c04-bc77-ec85347504e1.png?v=1781061044","url":"https:\/\/www.autooiltech.com\/products\/ge-369-hi-0-0-0-0-0-e-motor-protection-relay","provider":"AutoOilTech Limited","version":"1.0","type":"link"}