{"product_id":"fs-tsdo-0824-honeywell-safe-digital-output-fta","title":"FS-TSDO-0824 | Honeywell | Safe Digital Output FTA","description":"\u003ch3\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eHoneywell FS-TSDO-0824\u003c\/strong\u003e, also cataloged as the TSDO-0824 Safe Digital Output FTA, operates as a termination assembly for eight-channel 24 VDC solid-state outputs within Honeywell Safety Manager systems. It provides safe current-limited distribution with defined mechanical and electrical parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003eHardware \u003c\/span\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e TSDO-0824\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e USA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 3 Kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (D × W × H):\u003c\/strong\u003e 6 cm × 7 cm × 5.8 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e 0 to 60 deg C typical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC nominal (defined by connected output module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 8 digital outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 36 VDC (IEC 1010, overvoltage category 3)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Current per Channel:\u003c\/strong\u003e 1.5 A (actual maximum defined by connected module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRail Mounting:\u003c\/strong\u003e DIN EN TS32 \/ TS35 × 7.5, rail length 61 mm (2.40 in)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTerminals:\u003c\/strong\u003e Screw type, max wire diameter 2.5 mm² (AWG 14), strip length 7 mm (0.28 in), tightening torque 0.5 Nm (0.37 ft-lb)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003eChannel-to-Channel \u003c\/span\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe FS-TSDO-0824 employs \u003cstrong\u003echannel-to-channel isolation\u003c\/strong\u003e to ensure that overload or short-circuit conditions remain localized. Current limitation is defined by the connected output module, while mechanical termination ensures safe installation in hazardous environments. This design supports compliance with IEC and ATEX\/IECEx standards for safe output distribution.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003eFrequently \u003c\/span\u003e\u003cspan\u003eAsked \u003c\/span\u003e\u003cspan\u003eQuestions\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e Can the FS-TSDO-0824 be hot-swapped during operation? \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Hot-swap is supported when output circuits are isolated; loads must be de-energized before removal or insertion.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e How does the module handle overload detection? \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Overload protection is defined by the connected output module; the FTA provides safe mechanical termination only.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e What is the maximum wire size supported? \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The screw terminals support up to 2.5 mm² (AWG 14) conductors with a strip length of 7 mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47583808553150,"sku":"FS-TSDO-0824","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/FC-TSDI-1624_1.png?v=1779437578","url":"https:\/\/www.autooiltech.com\/products\/fs-tsdo-0824-honeywell-safe-digital-output-fta","provider":"AutoOilTech Limited","version":"1.0","type":"link"}