{"product_id":"fc-sdol-0424-honeywell-digital-output-module","title":"FC-SDOL-0424 | Honeywell | Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eHoneywell FC-SDOL-0424\u003c\/strong\u003e, also cataloged as the FC-SDOL-0424 Digital Output Module, operates as a dedicated hardware component for discrete signal switching within Experion PKS Series C systems. It provides four solid-state 24 VDC source outputs with short-circuit protection and defined load parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e FC-SDOL-0424\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e USA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 2 Kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 4 TE, 3 HE (4 HP, 3U)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e 0 to 60 deg C typical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 5 VDC 15 mA; 24 VDC internal 50 mA; 24 VDC external 15 mA (no load)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 4 solid-state source outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannel Current:\u003c\/strong\u003e Max 1 A per channel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTotal Module Load:\u003c\/strong\u003e 3.6 A (dissipation limit)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLoad Inductance:\u003c\/strong\u003e Max 0.5 H\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLoad Capacitance:\u003c\/strong\u003e Max 1 uF\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e \u0026lt; 1.3 V at 1 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOff Current:\u003c\/strong\u003e \u0026lt; 0.1 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe module integrates into Honeywell DCS architectures using\u003cstrong\u003e \u003c\/strong\u003e4-20 mA HART loop protocol. Channel-to-channel isolation ensures fault containment, while external 24 VDC supply separation maintains independent field power. Although cold junction compensation (CJC) is not applicable to digital outputs, Honeywell’s unified I\/O design maintains consistent signal integrity across mixed module types.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e Does the FC-SDOL-0424 support hot-swap replacement?\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, the module can be inserted or removed under power, provided output loads are de-energized during replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e What is the backplane current draw impact? \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module consumes 15 mA at 5 VDC from the backplane, which must be included in rack load calculations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e How does overload detection function? \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Overload detection triggers when load resistance falls below 10 ohms, initiating protective shutdown of the affected channel.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47583233769662,"sku":"FC-SDOL-0424","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/FC-SDO-0824_2.png?v=1779437022","url":"https:\/\/www.autooiltech.com\/products\/fc-sdol-0424-honeywell-digital-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}