{"product_id":"f60-ps-01-hima-himatrix-f60ps01-power-supply-module","title":"F60 PS 01 | HIMA HIMatrix | F60PS01 Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIMA F60 PS 01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the primary power conditioning unit for the HIMatrix F60 modular safety system.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-28 citation-end-28\"\u003eIt converts external 24 VDC plant power into regulated internal voltages for the central CPU and up to 6 communication or I\/O modules.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe module sits in Slot 1 of the F60 GEH 01 subrack to ensure stable, noise-filtered energy delivery for SIL 3 safety calculations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSystem power supply module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC (-15% to +20%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltages:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 VDC and 24 VDC internal system bus rails\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Certification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to SIL 3 (IEC 61508) and PL e (EN ISO 13849-1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated 10 A slow-blow fuse on the input side\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLess than 15 W at full system load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-27\"\u003e\u003c\/span\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan class=\"citation-27 citation-end-27\"\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +60°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAbsorb Voltage Fluctuations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module tolerates standard industrial voltage drops and spikes without dropping its internal output. It prevents nuisance safety CPU resets during heavy field motor startups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Sensitive Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated electromagnetic compatibility (EMC) filters block high-frequency noise from reaching the CPU and I\/O modules. It stabilizes safety calculations in heavy turbine halls and chemical refineries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOvercome Thermal Fatigue:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module transfers heat efficiently to the F60 GEH 01 subrack ventilation path. It runs cool at full load to double the mean time between failures (MTBF).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnose Supply Faults Fast:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBright front-panel LED indicators display input power status and internal rail health. Technicians isolate utility supply faults from internal hardware faults in seconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Can I hot-swap the F60 PS 01 module while the safety system is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou must shut down the system before removing the power supply module. Pulling the power supply module under load de-energizes the system backplane and triggers a safe state shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Does the module contain internal protection against reverse polarity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The F60 PS 01 incorporates reverse polarity diodes and overvoltage crowbar circuits to prevent internal trace burnouts during wiring accidents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: How does the system react if the input voltage drops below 18 VDC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module signals an undervoltage fault to the CPU via the backplane. The CPU then drives all field I\/O to their configured safe state before the internal capacitors drain completely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":46521834012862,"sku":"F60PS01","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/F60PS01F60PS01_1.jpg?v=1774253666","url":"https:\/\/www.autooiltech.com\/products\/f60-ps-01-hima-himatrix-f60ps01-power-supply-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}