{"product_id":"emerson-ve5009-enhanced-system-power-supply","title":"Emerson VE5009 Enhanced System Power Supply","description":"\u003cp\u003eConfigured for power distribution in DeltaV distributed control architectures, the \u003cstrong\u003eEmerson VE5009\u003c\/strong\u003e (\u003cstrong\u003eVE5009\u003c\/strong\u003e) System Power Supply provides direct physical\/electrical execution of 12 VDC and 24 VDC voltage regulation and input current conditioning.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVE5009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eIndustrial module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e14.8 A (12 VDC) \/ 6.1 A (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Protection\u003c\/td\u003e\n\u003ctd\u003eInternally fused, non-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEmerson DCS Process Control Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The VE5009 module provides a stabilized DC bus for HART-enabled I\/O cards. This stable power delivery is mandatory to maintain the signal-to-noise ratio required for reliable HART communication overlay on 4-20 mA loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The power supply architecture utilizes internal galvanic separation to isolate the system bus from field-side voltage spikes. This is mandatory to ensure that transient conditions on the 12 VDC or 24 VDC rails do not compromise the integrity of the process control logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The module is designed to operate within extreme thermal envelopes while maintaining regulated output voltages, which is mandatory to prevent thermal fluctuations from causing voltage drift in sensitive analog input loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the internal fuse on the VE5009 module field-replaceable?\u003c\/p\u003e\n\u003cp\u003eA: No. The input protection circuitry utilizes an internal, non-replaceable fuse. If the unit fails to pass input current, the entire module must be replaced to restore the power supply function.\u003c\/p\u003e\n\u003cp\u003eQ: Does the power supply support operation at temperatures exceeding 60 deg C?\u003c\/p\u003e\n\u003cp\u003eA: Operation is permitted up to 70 deg C, but output de-rating is mandatory between 60 deg C and 70 deg C. Refer to the manufacturer de-rating curves to determine the maximum permissible load at specific ambient temperatures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the module in a vibration-resistant rack capable of withstanding 10 g shock and specified vibration profiles. Ensuring the module is properly seated in the baseplate is mandatory to maintain electrical continuity for the 2-wire DC input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the module chassis to the system instrumentation ground. A low-impedance connection is mandatory to ensure the efficacy of internal overvoltage protection circuits and to shunt high-frequency noise from the DC bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate 2-wire DC input leads with appropriate torque to prevent intermittent power loss. Maintain a minimum separation of 150 mm from high-voltage AC lines; this isolation is mandatory to protect the DC output from inductive transients that could destabilize downstream DCS electronics.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":48077546946750,"sku":"VE5009","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-09_17-01-18_0929081e-e0d7-4b49-b949-03075d538386.png?v=1783589821","url":"https:\/\/www.autooiltech.com\/products\/emerson-ve5009-enhanced-system-power-supply","provider":"AutoOilTech Limited","version":"1.0","type":"link"}