{"product_id":"emerson-ve3007-deltav-mx-controller","title":"Emerson VE3007 DeltaV MX Controller","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson VE3007\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eVE3007\u003c\/strong\u003e MX Controller, operates as a dedicated hardware component for executing local control algorithms and database coordination within DeltaV network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVE3007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupplied by System Power Supply via 2-wide Power\/Controller Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 W typical, 7.0 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 A, non-replaceable fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRight slot of the 2-wide Power\/Controller Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Network Execution \u0026amp; Protocol Management\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \u0026amp; Profibus PA Connectivity:\u003c\/strong\u003e The controller processes high-density control blocks and manages communication links to FOUNDATION Fieldbus or Profibus PA segments via downstream carrier interface cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Channel-to-Channel Isolation:\u003c\/strong\u003e Passive trace networks across the carrier interface preserve physical channel isolation barriers, protecting internal 96 MB microprocessor memory layers from hazardous field-side electrical surges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeterministic Control Loop Execution:\u003c\/strong\u003e Operates as a master nodes interface on the DeltaV control network, executing discrete, analog, and complex control strategies without cycle-time degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the VE3007 controller be hot-swapped while the process is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, the module supports hot-swapping. If configured as a redundant pair on a 2-wide redundant controller carrier, the backup unit will seamlessly assume control without interrupting active field operations or resetting database states.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the action path if the internal 3.0 A fuse clears?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The 3.0 A fuses on the VE3007 are non-replaceable. If an overcurrent fault occurs and clears an internal fuse, the controller module must be removed from service and returned to an authorized service facility for component-level repair.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Carrier Alignment:\u003c\/strong\u003e Position the controller over the right-hand slot of the 2-wide Power\/Controller Carrier. Align the rear terminal connections with the mating pins before pressing the module firmly onto the carrier backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Earthing Verification:\u003c\/strong\u003e Confirm that the carrier is mounted on a standard metallic DIN rail that is bonded to the master cabinet grounding bar to ensure proper noise dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Locking Mechanics:\u003c\/strong\u003e Once the module is fully seated, tighten the dual integrated retaining screws at the top and bottom of the front bezel to ensure stable contact under operational vibration profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Cable Separation:\u003c\/strong\u003e Route redundant control network cables (Primary and Secondary) through independent routing ducts to reduce the risk of concurrent physical damage to both communication segments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":48164827562174,"sku":"VE3007","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-09_17-01-18_c72449ef-bdcb-43a0-ace6-9717d3f7db54.png?v=1784108196","url":"https:\/\/www.autooiltech.com\/products\/emerson-ve3007-deltav-mx-controller","provider":"AutoOilTech Limited","version":"1.0","type":"link"}