{"product_id":"emerson-pac8000-8202-ho-is-8-point-analog-output-module","title":"Emerson PAC8000 8202-HO-IS 8-Point Analog Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson PAC8000 \u003cstrong\u003e8202-HO-IS\u003c\/strong\u003e Analog Output Module delivers eight channels of 4–20 mA I\/P conversion with integrated HART functionality. Built for modular deployment in both general-purpose and hazardous area environments, this unit ensures reliable signal transmission, advanced diagnostics, and seamless integration with PAC8000 carriers and controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003e8202-HO-IS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Output Count \u0026amp; Type:\u003c\/strong\u003e 8-point 4–20 mA I\/P converters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResolution \u0026amp; Speed:\u003c\/strong\u003e 12-bit; 80 ms update; 1 s HART cycle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 630 mA (system)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFault Detection:\u003c\/strong\u003e Open-circuit field wiring detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHART Capabilities:\u003c\/strong\u003e Pass-through, variable reporting, and status monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModular PAC8000 I\/O design for flexible integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for hazardous area applications with robust safety compliance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOpen architecture supports multiple fieldbus communication options via BIM or controller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSnap-on field terminals for quick installation and replacement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanical keying system ensures safe and correct module placement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCarriers provide mechanical support and electrical backbone with Railbus connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated HART diagnostics for enhanced process visibility\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eChemical and petrochemical process control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOil \u0026amp; gas automation systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower generation and utility monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWater treatment and industrial manufacturing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What makes the PAC8000 series suitable for hazardous areas?\u003c\/strong\u003e A: The PAC8000 modules are designed with modular carriers and mechanical keying systems that maintain safety and compliance in hazardous environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the 8202-HO-IS module report HART variables directly?\u003c\/strong\u003e A: Yes, it supports HART variable and status reporting, along with pass-through functionality for advanced diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How are field terminals managed?\u003c\/strong\u003e A: Each I\/O module includes snap-on terminals that can be easily replaced if damaged, ensuring minimal downtime.\u003c\/span\u003e\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":46566620790974,"sku":"8202-HO-IS","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/8202-HO-IS.png?v=1775546912","url":"https:\/\/www.autooiltech.com\/products\/emerson-pac8000-8202-ho-is-8-point-analog-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}