{"product_id":"emerson-kl3104x1-ba1-i-s-do-45-ma-charm","title":"Emerson KL3104X1-BA1 I.S. DO 45 mA CHARM","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson KL3101X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(often identified in the S-series catalog as the KL3104X1-BA1) is an Intrinsically Safe (I.S.) Discrete Output Characterization Module (CHARM) designed for the DeltaV S-series platform. This module provides a controlled 45 mA output to drive field devices such as solenoid valves or indicators located in hazardous areas. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKL3104X1-BA1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntrinsically Safe Discrete Output (I.S. DO)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e45 mA rated output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Circuit Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e+24 VDC at 78 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCHARM Bus Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e+6.3 VDC at 0 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Limits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% Non-Condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10g ½ Sinewave for 11ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1mm Peak to Peak (2 to 13.2Hz); 0.7g (13.2 to 150Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContaminant Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eISA-S71.04 – 1985 Class G3 (Harsh)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Keying:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3E position for correct module-to-base alignment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Intrinsic Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDirectly supports hazardous area field devices by limiting energy to safe levels, significantly reducing cabinet wiring complexity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Marshalling Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePart of the DeltaV S-series ecosystem, allowing for channel-by-channel I\/O configuration and reducing overall hardware footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-242\"\u003e\u003c\/span\u003e\u003cstrong\u003eExtreme Environmental Protection:\u003c\/strong\u003e\u003cspan class=\"citation-242 citation-end-242\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures G3 conformal coating to resist the effects of corrosive gases and airborne contaminants in industrial sites.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Output Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a steady 45 mA signal, sufficient to power a wide range of low-power I.S. solenoids and field-mounted visual alarms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Coding:\u003c\/strong\u003e\u003cspan class=\"citation-241 citation-end-241\"\u003e\u003cspan\u003e \u003c\/span\u003eUses a specific 3E terminal block keying system to prevent the insertion of non-I.S. modules into safety-critical slots.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLive Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports hot-swapping functionality, enabling technicians to replace modules without powering down the entire I\/O carrier.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":46427596685502,"sku":"KL3104X1-BA1","price":750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/KL3103X1-BA1_2.png?v=1772078195","url":"https:\/\/www.autooiltech.com\/products\/emerson-kl3104x1-ba1-i-s-do-45-ma-charm","provider":"AutoOilTech Limited","version":"1.0","type":"link"}