{"product_id":"emerson-kl1604x1-ba1-safety-isolation-port","title":"Emerson | KL1604X1-BA1 | Safety Isolation Port","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eKL1604X1-BA1 \u003c\/strong\u003eSafety Isolation Port from Emerson is designed to provide secure isolation in distributed control and safety systems. With low power consumption and robust environmental endurance, it ensures reliable operation in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e: +5.0 VDC at 200 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: -40°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e: 10 g, ½ sine wave, 11 ms duration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVibration Tolerance\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 mm peak-to-peak, 2–13.2 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e0.7 g, 13.2–150 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAirborne Contaminants\u003c\/strong\u003e: Meets ISA-S71.04-1985 Class G3 standard\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e: 5–95%, non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafety instrumented systems requiring isolation between subsystems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHarsh industrial sites with high vibration and shock exposure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFacilities exposed to airborne contaminants where Class G3 compliance is critical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary function of the Safety Isolation Port?\u003c\/strong\u003e A: It provides electrical isolation between subsystems, ensuring safe and reliable communication in distributed control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can it operate in outdoor or semi-exposed environments?\u003c\/strong\u003e A: Yes, its wide temperature range and humidity tolerance make it suitable for outdoor or semi-exposed installations.\u003c\/span\u003e\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":46495194022078,"sku":"KL1604X1-BA1","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/emerson-ve4002s1t1b2-kj3001x1-bg1-12p0557x162-digital-output-isolated-24v-module-g4v5psxwb1x.png?v=1759052215","url":"https:\/\/www.autooiltech.com\/products\/emerson-kl1604x1-ba1-safety-isolation-port","provider":"AutoOilTech Limited","version":"1.0","type":"link"}