{"product_id":"emerson-ez1080-05-00-010-eddy-current-sensor","title":"Emerson EZ1080-05-00-010 Eddy Current Sensor","description":"\u003cp\u003eConfigured for precision shaft vibration and displacement monitoring in AMS monitoring networks, the \u003cstrong\u003eEmerson EZ1080-05-00-010\u003c\/strong\u003e (\u003cstrong\u003eEZ1080-05-00-010\u003c\/strong\u003e Eddy Current Sensor) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \u0026amp; Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEZ1080\u003c\/td\u003e\n\u003ctd\u003eSeries Code\u003c\/td\u003e\n\u003ctd\u003eAMS 8 mm eddy current probe platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eProbe Length Code\u003c\/td\u003e\n\u003ctd\u003e50 mm probe body length variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eCable Length Option\u003c\/td\u003e\n\u003ctd\u003e1 meter integral cable variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e010\u003c\/td\u003e\n\u003ctd\u003eConnector \u0026amp; Thread Option\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 threaded body with standard industrial termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEZ1080-05-00-010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGlobal Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.10 kg (with 1 meter cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e50 mm probe length, M10 x 1 thread size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +180 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via compatible eddy current converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eFEP-jacketed non-armored coaxial cable (1 meter length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP67 standard (IP68 optional with test certification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe signal conditioning electronics paired with this sensor process high-frequency oscillator inputs to output standardized signals compatible with 4-20 mA HART loop protocol architectures. Channel-to-channel isolation design prevents ground loops and electrical noise propagation across multi-channel industrial monitoring systems. Internal regulation circuitry maintains stable negative excitation voltage rails, ensuring signal linearity and dynamic vibration measurement precision across extended operational lifecycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the required gap voltage calibration target during initial mechanical setup?\u003c\/p\u003e\n\u003cp\u003eA: The probe gap should be adjusted mechanically until the static output voltage reaches the nominal midpoint target corresponding to the linear operating range of the connected converter.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 1 meter integral FEP cable be shortened or spliced in the field?\u003c\/p\u003e\n\u003cp\u003eA: No. The probe assembly, integral cable, and converter module are factory-calibrated as a matched electrical system. Altering cable length changes total electrical capacitance and invalidates calibration accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: What is the minimum target shaft diameter required for accurate measurement?\u003c\/p\u003e\n\u003cp\u003eA: The rotating shaft target diameter must be at least three times the probe tip diameter (minimum 24 mm for an 8 mm tip) to prevent edge effect errors on the electromagnetic eddy-current field.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the mounting hole is threaded cleanly with an M10 x 1 tap, and deburr the entry point to prevent physical damage to the glass-fiber reinforced PEEK probe tip during mechanical seating.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum radial clearance distance of 25 mm between adjacent probe tips to eliminate mutual electromagnetic cross-talk between monitoring channels.\u003c\/li\u003e\n\u003cli\u003eRoute the coaxial signal cable away from high-power motor leads and variable frequency drive output conduits, securing the shield drain wire at the designated panel ground bar.\u003c\/li\u003e\n\u003cli\u003eVerify loop DC resistance and static output voltage using a high-impedance digital multimeter prior to system energization and machinery startup.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":48179983483070,"sku":"EZ1080-05-00-010","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/EZ1080-05-00-010_6bea97cf-6b6b-47e8-90ee-e4e283425570.png?v=1784627489","url":"https:\/\/www.autooiltech.com\/products\/emerson-ez1080-05-00-010-eddy-current-sensor","provider":"AutoOilTech Limited","version":"1.0","type":"link"}