{"product_id":"emerson-epro-con021-916-240-pr6426-010-140-eddy-current-sensor-converter","title":"Emerson Epro CON021\/916-240+PR6426\/010-140 Eddy Current Sensor Converter","description":"\u003cp\u003e\u003cstrong\u003eSystem Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis measurement chain is a specialized, long-distance configuration of the\u003cstrong\u003e \u003c\/strong\u003eMMS 6000\/3000 series. It combines the \u003cstrong\u003eCON021\u003c\/strong\u003e converter with the \u003cstrong\u003ePR6426\u003c\/strong\u003e high-temperature probe. This specific set is calibrated for a 24-meter total system length, which is typically required in massive hydro-generators or large-scale steam turbine halls where the instrumentation cabinets are located at a significant distance from the machine bearings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent 1: CON021\/916-240 Signal Converter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\/916-240\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the driver\/transmitter. The \"916-240\" suffix is the critical hardware identifier, indicating internal compensation for the impedance and capacitance of a 24-meter cable run.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCON021\/916-240\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExactly 24.0 meters (Total of probe cable + extension cable).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandardized analog voltage, typically\u003cspan\u003e \u003c\/span\u003e0 to -20 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOscillator\/Demodulator that maintains a stable electromagnetic field at the probe tip despite the long cable attenuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShielded aluminum housing for DIN-rail mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eComponent 2: PR6426\/010-140 Displacement Sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6426\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the \"Heavy Duty\" variant of the Epro displacement sensors, designed for high-pressure and high-temperature zones within the turbine casing.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePR6426\/010-140\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTip Diameter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApproximately\u003cspan\u003e \u003c\/span\u003e2.0 mm\u003cspan\u003e \u003c\/span\u003e(Nominal).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral Cable (010):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.0-meter integral cable length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection (140):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStainless steel flexible armored conduit with high-temperature insulation (FEP\/PFA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-355\"\u003e\u003c\/span\u003e\u003cstrong\u003eEnvironmental Limits:\u003c\/strong\u003e\u003cspan class=\"citation-355\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to withstand temperatures up to \u003c\/span\u003e180°C\u003cspan class=\"citation-355 citation-end-355\"\u003e and high-pressure oil environments.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Performance Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Reach:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 24-meter calibration (916-240) is among the longest standard configurations available, allowing for centralized monitoring in very large plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypically calibrated to 8 V\/mm\u003cspan\u003e \u003c\/span\u003e(200 mV\/mil) when matched with the 24m driver and a standard 42CrMo4 steel target.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity Window:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides accurate displacement data between -2 VDC and -18 VDC of the output signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\"Sensor OK\" Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe system continuously monitors the 24m loop; if the cable is cut or the probe is damaged, the voltage moves outside the \"OK\" window, alerting the DCS\/PLC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":46427767210174,"sku":"CON021\/916-240+PR6426\/010-140","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/emerson-pr6426-010-000-con021-916-160-epro-plc-module-prkonccuvzg.png?v=1772092696","url":"https:\/\/www.autooiltech.com\/products\/emerson-epro-con021-916-240-pr6426-010-140-eddy-current-sensor-converter","provider":"AutoOilTech Limited","version":"1.0","type":"link"}