{"product_id":"emerson-epro-con021-916-200-pr6426-010-140-eddy-current-signal-converter","title":"Emerson Epro CON021\/916-200+PR6426\/010-140 Eddy Current Signal Converter","description":"\u003cp\u003e\u003cstrong\u003eSystem Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis measurement chain is a high-precision, non-contacting displacement system designed for critical machinery protection. It combines the\u003cstrong\u003e CON021\/916-200\u003c\/strong\u003e driver with the \u003cstrong\u003ePR6426\/010-140 \u003c\/strong\u003ehigh-temperature probe. This specific set is calibrated for a 20-meter total system length, making it ideal for large-scale power plant turbines where the sensor is located deep within the machine and the electronics must be housed in a remote, protected cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponent 1: CON021\/916-200 Signal Converter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\/916-200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the oscillator and demodulator. The \"916-200\" suffix is the most critical specification, as it dictates the internal tuning for cable impedance over a long distance.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCON021\/916-200\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExactly 20.0 meters (Total of probe cable + extension cable).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandardized analog voltage, typically 0 to -20 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized to provide a constant sensitivity (slope) across the 20m run.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e35mm DIN-rail compatible with a shielded aluminum housing to prevent EMI interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eComponent 2: PR6426\/010-140 Displacement Sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-349\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003ePR6426\u003c\/strong\u003e\u003cspan class=\"citation-349 citation-end-349\"\u003e\u003cspan\u003e \u003c\/span\u003eis the \"Heavy Duty\" variant of the Epro eddy current probes, specifically engineered for high-temperature and high-pressure environments.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-348\"\u003e\u003c\/span\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan class=\"citation-348 citation-end-348\"\u003e\u003cspan\u003e \u003c\/span\u003ePR6426\/010-140\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTip Diameter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.0 mm (Nominal).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral Cable (010):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.0-meter integral cable length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection (140):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"140\" suffix typically specifies a stainless steel flexible armored conduit with a specific high-temperature FEP\/PFA cable and a specialized terminal connector (often a LEMO or similar high-vibration plug).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e\u003cspan class=\"citation-347\"\u003e\u003cspan\u003e \u003c\/span\u003eTip rated for up to \u003c\/span\u003e180°C (356°F)\u003cspan class=\"citation-347 citation-end-347\"\u003e, suitable for mounting near high-pressure steam seals or within bearing housings.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Performance Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypically 8 V\/mm (200 mV\/mil) when matched with the 20m driver and a standard steel target (42CrMo4).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Reach:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 20-meter capability allows for the converter to be placed far from the \"hot zone,\" increasing the lifespan of the electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides high-speed data for axial thrust, radial vibration, and eccentricity monitoring in the MMS 6000 or Ovation systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"Sensor OK\" window is usually between -2V and -18V. If the voltage drops to 0V (short) or rises toward the supply voltage (open), the system triggers a channel fault.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":45445543166142,"sku":"CON021\/916-200+PR6426\/010-140","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/emerson-pr6426-010-000-con021-916-160-epro-plc-module-htskuq3rcnd.png?v=1772092696","url":"https:\/\/www.autooiltech.com\/products\/emerson-epro-con021-916-200-pr6426-010-140-eddy-current-signal-converter","provider":"AutoOilTech Limited","version":"1.0","type":"link"}