{"product_id":"emerson-deltav-kj3222x1-ba1-12p2532x152-ce4003s2b3-analog-input-module","title":"Emerson DeltaV KJ3222X1-BA1 (VE4003S2B3) 8-Channel Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson DeltaV KJ3222X1-BA1 (also identified as VE4003S2B3) is a high-performance 8-channel Analog Input module designed for the DeltaV S-Series scalable process control system. This module provides high-precision data acquisition for 4-20 mA signals and includes integrated HART digital communication, enabling advanced diagnostics and remote instrument configuration directly from the control room. It is engineered for mission-critical reliability in demanding industrial environments, including oil and gas, chemical processing, and power generation.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8-channel analog input with HART communication support.\u003c\/li\u003e\n\u003cli\u003eDesigned for the DeltaV S-Series I\/O subsystem.\u003c\/li\u003e\n\u003cli\u003eIntegrated diagnostics for improved loop health monitoring.\u003c\/li\u003e\n\u003cli\u003eRotary keying system for secure mechanical alignment with terminal blocks.\u003c\/li\u003e\n\u003cli\u003eSupports both Local Bus Power and Bussed Field Power.\u003c\/li\u003e\n\u003cli\u003eCertified for use in hazardous atmosphere Zone 2 environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is typically deployed in process automation systems requiring high-density analog signal processing. It is suitable for monitoring field instruments such as pressure, flow, level, and temperature transmitters in refineries, petrochemical plants, and utility facilities where HART-enabled device management is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3222X1-BA1 \/ VE4003S2B3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS-Series (Series 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Bus Power\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBussed Field Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 30 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10 g (11 ms half-sine)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Tolerance\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak (2-13.2 Hz); 0.7 g (13.2-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Rating\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3 (Harsh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKey Position\u003c\/td\u003e\n\u003ctd\u003eA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the carrier.\u003c\/li\u003e\n\u003cli\u003eVerify the rotary key position (A1) matches the corresponding terminal block to prevent hardware mismatch.\u003c\/li\u003e\n\u003cli\u003eThe module is a factory-calibrated, non-serviceable unit; do not attempt to open the housing.\u003c\/li\u003e\n\u003cli\u003eEnsure all wiring for energy-limited nodes is assessed for loop safety and signal integrity.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding and shielding practices to minimize EMI in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation in the cabinet to maintain operating temperatures within the specified -40 to +70 deg C range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\u003cp\u003eThis module complies with hazardous area requirements including FM13ATEX0034U and IECEx FMG 13.0015U. Protection methods include II 3 G Ex nA [ic] IIC Gc and II 3 G Ex nA [nL] IIC Gc.\u003c\/p\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eIs this module compatible with older DeltaV systems?\u003c\/strong\u003e\u003cbr\u003eThis is an S-Series (Series 2) module. Please verify your existing carrier and system revision to ensure compatibility with S-Series hardware.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module support HART?\u003c\/strong\u003e\u003cbr\u003eYes, the KJ3222X1-BA1 supports HART digital communication on all 8 channels, allowing for instrument configuration and diagnostics.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I repair this module if it fails?\u003c\/strong\u003e\u003cbr\u003eNo, this is a non-serviceable, factory-calibrated unit. Any attempt to open the module will void its certification and integrity.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":48651479974078,"sku":"KJ3222X1-BA1 12P2532X152 CE4003S2B3","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_b0c4f23f-882d-4690-9bdc-49925ecf587e.jpg?v=1786154213","url":"https:\/\/www.autooiltech.com\/products\/emerson-deltav-kj3222x1-ba1-12p2532x152-ce4003s2b3-analog-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}