{"product_id":"emerson-deltav-kj1501x1-bk1-s-series-dc-dc-system-power-supply","title":"Emerson DeltaV KJ1501X1-BK1 S-Series DC\/DC System Power Supply","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eKJ1501X1-BK1\u003c\/strong\u003e DC\/DC System Power Supply from Emerson’s DeltaV S-Series delivers stable and efficient power conversion for distributed control systems. Designed for rugged industrial environments, it ensures reliable operation of controllers and I\/O modules under demanding conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e: \u003cstrong\u003eKJ1501X1-BK1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: DC\/DC system power supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e: 19.2 VDC to 28.8 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Ratings\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e12 VDC\u003c\/strong\u003e: 8 A max (up to 60 °C), 6 A max (up to 70 °C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e5.1 VDC\u003c\/strong\u003e: 2.0 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e3.4 VDC\u003c\/strong\u003e: 2.0 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTotal Output Power\u003c\/strong\u003e: 10.2 W at 70 °C (combined 5 VDC + 3.3 VDC outputs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAmbient Temperature: \u003c\/strong\u003e-40 °C to +70 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShock:\u003c\/strong\u003e 10 g, ½ sinewave for 11 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVibration: \u003c\/strong\u003e1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5–95% non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAirborne Contaminants:\u003c\/strong\u003e ISA-S71.04 Class G3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDesign Features\u003c\/strong\u003e: Compact form factor, high reliability, optimized for continuous operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePowering DeltaV controllers and I\/O subsystems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation requiring stable DC\/DC conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHarsh environments with wide temperature ranges and airborne contaminants\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the main function of the KJ1501X1-BK1?\u003c\/strong\u003e A: It converts DC input into regulated outputs (12 VDC, 5 VDC, 3.3 VDC) for DeltaV system modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can it operate in extreme environments?\u003c\/strong\u003e A: Yes, it supports -40 °C to +70 °C operation and meets ISA-S71.04 Class G3 standards for airborne contaminants.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How does it ensure reliability?\u003c\/strong\u003e A: It includes overload protection, wide input tolerance, and compliance with industrial shock and vibration standards.\u003c\/span\u003e\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":46447573795006,"sku":"KJ1501X1-BK1","price":740.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/emerson-kj3208x1-bk1-12p4699x052-digital-output-module-cag4qwgykuo.png?v=1775546656","url":"https:\/\/www.autooiltech.com\/products\/emerson-deltav-kj1501x1-bk1-s-series-dc-dc-system-power-supply","provider":"AutoOilTech Limited","version":"1.0","type":"link"}