{"product_id":"emerson-a0760gp-industrial-accelerometer","title":"Emerson A0760GP Industrial Accelerometer","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson A0760GP\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eA0760GP\u003c\/strong\u003e Industrial Accelerometer, operates as a dedicated hardware component for dynamic vibration monitoring within machinery health analysis systems. The piezoelectric transducer converts mechanical shock and rotational acceleration into a proportional AC voltage output. It provides continuous signal transmission to monitoring instrumentation across an excitation supply range of 18-28 VDC.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA0760GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard industrial sensor housing (1\/4-28 UNF-2B thread)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-54 to 121 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e18-28 VDC excitation current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mV\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Range\u003c\/td\u003e\n\u003ctd\u003e+\/- 50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Interface\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF-2B female thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e2-pin MIL-C-5015 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Construction\u003c\/td\u003e\n\u003ctd\u003eWelded hermetic seal, stainless steel case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Conditioning and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Emerson A0760GP interface incorporates internal signal conditioning designed to maintain channel-to-channel isolation when connected to multi-channel data acquisition hardware. The welded stainless steel enclosure provides a Faraday shield around the sensing element, preventing high-frequency electromagnetic field interference from distorting the 100 mV\/g voltage output. Ground isolation at the mounting interface attenuates ground loop currents, ensuring stable dynamic response across the full -54 to 121 deg C operating temperature spectrum.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power supply parameters are required to excite the Emerson A0760GP accelerometer?\u003c\/p\u003e\n\u003cp\u003eA: The sensor requires a constant current DC excitation voltage source operating within 18-28 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What connector type is required for field cable attachment to the Emerson A0760GP?\u003c\/p\u003e\n\u003cp\u003eA: The top-exit interface features a standard 2-pin MIL-C-5015 threaded military connector.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental protection is provided by the sensor casing?\u003c\/p\u003e\n\u003cp\u003eA: The sensor utilizes a stainless steel case with welded hermetic sealing, preventing moisture ingress and chemical contamination across temperature extremes of -54 to 121 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePrepare the machine mounting surface by spot-facing to a surface flatness within 0.001 inches TIR.\u003c\/li\u003e\n\u003cli\u003eApply a light film of silicone grease to the mounting interface to optimize high-frequency acoustic coupling.\u003c\/li\u003e\n\u003cli\u003eThread the mounting stud into the 1\/4-28 UNF-2B base tap and torque the sensor housing to 2 to 5 ft-lbs (2.7 to 6.8 Nm).\u003c\/li\u003e\n\u003cli\u003eAlign the 2-pin MIL-C-5015 cable connector keyway and hand-tighten the threaded coupling ring until fully seated.\u003c\/li\u003e\n\u003cli\u003eSecure the sensor cable within 6 inches of the connector using cable clamps to eliminate strain on the connector pins and prevent triboelectric noise generation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":48707401580734,"sku":"A0760GP","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/A0760GP_e19833b9-b259-4ef9-8513-bc17dbb16e8e.png?v=1786608994","url":"https:\/\/www.autooiltech.com\/products\/emerson-a0760gp-industrial-accelerometer","provider":"AutoOilTech Limited","version":"1.0","type":"link"}