{"product_id":"bmxddo6402k-schneider-modicon-x80-discrete-output-module","title":"BMXDDO6402K | Schneider Modicon X80 | Discrete Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eBMXDDO6402K\u003c\/strong\u003e discrete output module from Schneider Electric’s Modicon X80 series provides 64 solid-state DC outputs with diagnostic capability and integrated protection. Designed for automation platforms, it ensures reliable signal switching and safe operation in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMain Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e Modicon X80\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Discrete Output Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e 64 channels (IEC 61131-2 compliant)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Solid state\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLogic:\u003c\/strong\u003e Positive\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24 V DC (19…30 V range)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 0.1 A per channel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eComplementary Specifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent per Channel:\u003c\/strong\u003e 0.125 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Current per Module:\u003c\/strong\u003e 6.4 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e \u0026gt; 10 MΩ at 500 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 6.85 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 1.2 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eParalleling of Outputs:\u003c\/strong\u003e Supported (up to 3 channels)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTypical Current Consumption:\u003c\/strong\u003e 160 mA at 3.3 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMTBF:\u003c\/strong\u003e 150,000 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection Functions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eExternal fuse:\u003c\/strong\u003e 2 A fast blow for short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReverse polarity protection:\u003c\/strong\u003e Reverse-mounted diode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOverload protection:\u003c\/strong\u003e Current limiter and electronic circuit breaker (0.125 A \u0026lt; Id \u0026lt; 0.185 A)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOvervoltage protection:\u003c\/strong\u003e Transil diode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVoltage detection thresholds:\u003c\/strong\u003e \u0026lt; 14 V DC (pre-actuator fault), \u0026gt; 18 V DC (pre-actuator OK)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum tungsten load:\u003c\/strong\u003e 1.2 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Frequency:\u003c\/strong\u003e 0.5\/LI² Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Overload Time:\u003c\/strong\u003e 15 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLoad Impedance:\u003c\/strong\u003e ≥ 220 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRUN LED (green):\u003c\/strong\u003e Module operating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannel LEDs (green):\u003c\/strong\u003e Diagnostics per channel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e+32 Channels LED (green):\u003c\/strong\u003e Indicates channel group status\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eERR LED (red):\u003c\/strong\u003e Module error\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eI\/O LED (red):\u003c\/strong\u003e Module I\/O status\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Characteristics:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.15 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Characteristics:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDielectric Strength:\u003c\/strong\u003e 1500 V AC (output\/ground, output\/internal logic), 500 V DC (between channel groups)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 3 gn\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 30 gn\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40…85 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0…60 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5…95 % at 55 °C (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAltitude:\u003c\/strong\u003e 0…2000 m; up to 5000 m with derating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e 2014\/35\/EU Low Voltage Directive, 2014\/30\/EU EMC Directive\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eBMXDDO6402K \u003c\/strong\u003eis ideal for Modicon X80 automation platforms requiring high-density discrete output control. It is widely used in manufacturing, energy, and process industries where reliable signal switching and protection are critical.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many outputs does BMXDDO6402K provide?\u003c\/strong\u003e A: It offers 64 solid-state discrete outputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the module support output paralleling?\u003c\/strong\u003e A: Yes, up to 3 outputs can be paralleled.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What protection features are included?\u003c\/strong\u003e A: Reverse polarity, overload, overvoltage, and short-circuit protection are integrated\u003c\/span\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46451146653886,"sku":"BMXDDO6402K","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/schneider-electric-bmxddi1602-digital-i-o-module-eqlltalv3r0.png?v=1772510006","url":"https:\/\/www.autooiltech.com\/products\/bmxddo6402k-schneider-modicon-x80-discrete-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}