{"product_id":"bently-nevada-330105-02-12-15-02-05-3300-xl-8-mm-reverse-mount-probes","title":"Bently Nevada 330105-02-12-15-02-05 3300 XL 8 mm Reverse Mount Probes","description":"\u003ch2\u003eBently Nevada 330105-02-12-15-02-05 3300 XL 8 mm Proximity Transducer System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330105-02-12-15-02-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330105\u003c\/strong\u003e proximity transducer system, operates as a dedicated 8 mm eddy‑current measurement assembly for displacement and rotor‑dynamic monitoring across 3300 XL platforms. The unit implements a 0.5 m coaxial lead with ClickLoc termination and multiple agency approvals under suffix \u003cstrong\u003e05\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330105\u003c\/strong\u003e: 8 mm proximity transducer system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: Connector option = Miniature ClickLoc coaxial connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12\u003c\/strong\u003e: Unthreaded length = Not specified in input (base transducer system variant)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15\u003c\/strong\u003e: Total cable length = 1.5 m (1.6 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: Standard cable with ClickLoc termination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: Multiple agency approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ci\u003e(Input does not provide detailed mechanical segmentation for the 330105 series beyond cable and approval options; no additional suffix logic is inferred.)\u003c\/i\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e330105-02-12-15-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eNot specified (shipping weight 1.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eNot specified (transducer system assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003eNot specified (standard 3300 XL ambient expectations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003ePassive transducer; powered by proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProbe Type\u003c\/th\u003e\n\u003ctd\u003e3300 XL 8 mm proximity transducer system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCable Length\u003c\/th\u003e\n\u003ctd\u003e0.5 m (1.6 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003ctd\u003eMiniature ClickLoc coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003e05 = Multiple approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure Seal\u003c\/th\u003e\n\u003ctd\u003eViton O‑ring (standard 3300 XL sealing design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation and Eddy‑Current Scaling\u003c\/h3\u003e\n\u003cp\u003e3300 XL transducer systems maintain a −10 VDC nominal gap‑voltage reference to ensure linear displacement scaling across the 8 mm sensing range. The short 0.5 m cable minimizes impedance variation, improving phase stability and rotor‑dynamic correlation. ClickLoc termination provides repeatable electrical seating, reducing cross‑talk and maintaining consistent channel‑to‑channel behavior in multi‑probe installations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the transducer system be replaced while the proximitor remains energized? A: Replacement should occur only with the channel de‑energized to prevent transient gap‑voltage excursions.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 0.5 m cable length require proximitor recalibration? A: No recalibration is required; the cable length is factory‑matched for standard 3300 XL proximitor modules.\u003c\/p\u003e\n\u003cp\u003eQ: Do the multiple approvals under suffix 05 affect installation? A: Approvals do not alter electrical behavior; installation requirements remain identical to standard 3300 XL probes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain clean mounting surfaces to ensure stable mechanical seating.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shielding at the proximitor end only to prevent ground‑loop formation.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp bends that may alter coaxial impedance.\u003c\/li\u003e\n\u003cli\u003eRoute cable away from high‑current conductors to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify ClickLoc connector engagement before energizing the monitoring channel.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45440355434686,"sku":"330105-02-12-15-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/bently-nevada-330105-02-12-15-02-05-3300-xl-8-mm-reverse-mount-probes-zcxcds4k4a2_7eb4be3c-9b1e-43f4-8dde-0c8de994fd47.png?v=1759030042","url":"https:\/\/www.autooiltech.com\/products\/bently-nevada-330105-02-12-15-02-05-3300-xl-8-mm-reverse-mount-probes","provider":"AutoOilTech Limited","version":"1.0","type":"link"}