{"product_id":"amm22c-yokogawa-mv-input-multiplexer-module","title":"AMM22C | Yokogawa | MV Input Multiplexer Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AMM22C\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAMM22C\u003c\/strong\u003e MV Input Multiplexer Module, operates as a dedicated hardware component for low-level voltage data acquisition within CENTUM CS and CENTUM VP Distributed Control System networks. This module multiplexes millivolt-level analog inputs across independent sensor paths, executing high-resolution analog-to-digital conversion directly on localized low-voltage measurement loops before transmitting the serialized data registers to the host DCS processing nodes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAMM22C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard AMM-series interface card weight profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard compact nested DCS module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C standard industrial operating limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eConfiguration dependent via host DCS baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMV Input Multiplexer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS \/ CENTUM VP Distributed Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003eMillivolt (mV) analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation (Channel-to-Channel and Channel-to-Ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Configuration\u003c\/td\u003e\n\u003ctd\u003eStandard nested DCS baseplate slot insertion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterconnect Interface\u003c\/td\u003e\n\u003ctd\u003eCompatible with factory-standard multi-conductor system cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation (CJC) and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe internal matrix of the AMM22C features high-integrity channel-to-channel isolation designed to eliminate common-mode voltage transfer and prevent stray ground loops from distorting sensitive, low-level millivolt telemetry. When processing low-range analog inputs, the board utilizes highly integrated cold junction compensation (CJC) and precise thermal baseline reference tracking to eliminate ambient measurement drift at the termination field layer. This robust shielding and hardware-driven noise suppression structure allow the module to isolate and digitize microvolt-level variations accurately, preserving signal linearity across the entire distributed control bus topology.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the AMM22C handle high-frequency electrical noise or induction on the millivolt field lines?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on a combination of rigorous channel-to-channel galvanic isolation and internal low-pass analog filtering. This layout attenuates high-frequency common-mode noise and electromagnetic interference before the raw field signal passes into the analog-to-digital conversion matrix, preventing data corruption or register jitter.\u003c\/p\u003e\n\u003cp\u003eQ: Can high-voltage 24 VDC instrument loops be connected directly to the AMM22C input terminal blocks?\u003c\/p\u003e\n\u003cp\u003eA: No. The AMM22C input circuitry is engineered and scaled exclusively for low-level millivolt (mV) thresholds. Wiring standard high-voltage 24 VDC or 0-10 V industrial signals to these specialized channels will saturate the conversion matrix and can cause permanent dielectric puncture or thermal destruction of the input components.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Signal Shield Grounding\u003c\/strong\u003e: Run all millivolt field connections via high-density shielded twisted-pair (STP) cabling, and ensure the drain wire is terminated at a clean, single instrumentation ground bar within the cabinet enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Thermal Equilibrium\u003c\/strong\u003e: Avoid installing the module immediately adjacent to heavy internal heat sources, such as power supplies or line reactors, to maintain uniform ambient temperature conditions around the reference circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Contact Integrity\u003c\/strong\u003e: Verify that all field conductors are stripped cleanly and torqued down evenly to the terminal block screws, as loose connections on millivolt inputs can generate parasitic resistance and large measurement errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Routing Separation\u003c\/strong\u003e: Maintain a strict physical separation between all low-level millivolt input conduits and high-current AC power distribution cables to minimize external inductive coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":47589360206014,"sku":"AMM22C","price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/AMM12_1.jpg?v=1779939011","url":"https:\/\/www.autooiltech.com\/products\/amm22c-yokogawa-mv-input-multiplexer-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}