{"product_id":"allen-bradley-2711p-rn3-panelview-plus-communication-module","title":"Allen-Bradley 2711P-RN3 PanelView Plus Communication Module","description":"\u003cp\u003eConfigured for DH-485 network protocol integration in PanelView Plus 400 and 600 terminals, the \u003cstrong\u003eAllen-Bradley 2711P-RN3\u003c\/strong\u003e (\u003cstrong\u003e2711P-RN3\u003c\/strong\u003e Communication Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-RN3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.56 lbs (0.26 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact plug-in module for PanelView Plus 400\/600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C (32 to 131 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via terminal internal backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eDH-485 network protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHMI Compatibility\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 400 and PanelView Plus 600 terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Length\u003c\/td\u003e\n\u003ctd\u003e30 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003ePlug-and-play\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicator Type\u003c\/td\u003e\n\u003ctd\u003eDiagnostic LED indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration \/ Shock\u003c\/td\u003e\n\u003ctd\u003eOperating shock: 15 G; Non-operating shock: 30 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePanelView Plus Communication \u0026amp; Backplane Bus Integration\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-RN3 attaches to small-logic operator interface terminals to facilitate multi-node DH-485 serial communication. Operating across distances up to 30 meters, the interface board establishes real-time register mapping without impacting terminal display rendering or backplane bus communication velocity across internal processing channels. Integrated diagnostic LED indicators provide local status monitoring during active network transmission.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 2711P-RN3 support hot-swapping while the PanelView Plus terminal is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. Power to the PanelView Plus terminal must be removed before inserting or extracting the 2711P-RN3 communication module to prevent interface circuit damage.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum recommended transmission distance for the DH-485 interface on this module?\u003c\/p\u003e\n\u003cp\u003eA: The specification limits the DH-485 connection cable length for this module to 30 meters.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all operating power sources from the PanelView Plus terminal before beginning installation.\u003c\/li\u003e\n\u003cli\u003eMaintain standard electrostatic discharge (ESD) precautions by utilizing a grounded anti-static wrist strap.\u003c\/li\u003e\n\u003cli\u003eRemove the expansion module cover plate on the rear of the PanelView Plus 400 or 600 terminal.\u003c\/li\u003e\n\u003cli\u003eAlign the 2711P-RN3 module connector with the terminal backplane socket and press firmly until fully seated.\u003c\/li\u003e\n\u003cli\u003eSecure the retaining screws, connect the DH-485 network cable within the 30-meter limit, and verify terminal communications upon power-up.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":48747670536382,"sku":"2711P-RN3","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/2711P-RN3_1.jpg?v=1786957518","url":"https:\/\/www.autooiltech.com\/products\/allen-bradley-2711p-rn3-panelview-plus-communication-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}