{"product_id":"allen-bradley-1769-ecr-compact-i-o-end-cap-module","title":"Allen Bradley 1769-ECR Compact I\/O End Cap Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003e1769-ECR\u003c\/strong\u003e Compact I\/O End Cap Module from Allen-Bradley is designed to terminate the Compact I\/O bus in a right-end configuration. It provides proper electrical isolation and ensures reliable communication across the Compact I\/O system. This module is essential for maintaining system integrity when no additional modules are connected to the right side of the I\/O assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMain Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e Compact I\/O 1769\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType:\u003c\/strong\u003e End Cap Module (Right-End Terminator)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Provides bus termination and electrical isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e CompactLogix controllers and Compact I\/O modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e Mounted at the right end of the I\/O module chain\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSlot Width:\u003c\/strong\u003e 1 standard slot\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting Options:\u003c\/strong\u003e DIN rail or panel mount\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePerformance and Reliability:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsures proper termination of the Compact I\/O bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrevents communication errors and electrical interference\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLightweight and easy to install\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRequired for all Compact I\/O configurations without additional modules on the right end\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Characteristics:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFormat:\u003c\/strong\u003e Compact I\/O standard module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e Approx. 0.2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Compact I\/O standard size\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe\u003cstrong\u003e 1769-ECR\u003c\/strong\u003e is used in CompactLogix and MicroLogix 1500 systems to terminate the I\/O bus. It is essential in automation setups where the I\/O module chain ends without further expansion, ensuring reliable communication and system stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the purpose of the 1769-ECR module?\u003c\/strong\u003e A: It serves as a right-end terminator for the Compact I\/O bus, ensuring proper electrical isolation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the 1769-ECR required in all Compact I\/O systems?\u003c\/strong\u003e A: Yes, it must be installed at the end of the I\/O module chain if no additional modules are connected.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How is the module mounted?\u003c\/strong\u003e A: It supports both DIN rail and panel mounting.\u003c\/span\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46451342934206,"sku":"1769-ECR","price":630.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/1769-ECR_1.jpg?v=1774238438","url":"https:\/\/www.autooiltech.com\/products\/allen-bradley-1769-ecr-compact-i-o-end-cap-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}