{"product_id":"allen-bradley-100-fsv136-surge-suppressor-module","title":"Allen-Bradley 100-FSV136 Surge Suppressor Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 100-FSV136\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e100-FSV136\u003c\/strong\u003e Surge Suppressor Module, operates as a dedicated hardware component for transient voltage spike attenuation within Bulletin 100 contactor and control circuits. The varistor-based circuit clamps high-voltage transients generated by inductive load switching, maintaining voltage levels within specified limits across 56-136 VAC or 78-180 VDC control lines.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e100-FSV136\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eBulletin 100 Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eSurge Suppressors \/ Panel Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.05 lbs (0.02 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact Plug-in Contact Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Negligible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (AC)\u003c\/td\u003e\n\u003ctd\u003e56-136 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (DC)\u003c\/td\u003e\n\u003ctd\u003e78-180 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuppressor Technology\u003c\/td\u003e\n\u003ctd\u003eMetal Oxide Varistor (MOV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication \u0026amp; Hardware Execution\u003c\/h3\u003e\n\u003cp\u003eIntegrated directly onto the contactor coil terminals, the \u003cstrong\u003e100-FSV136\u003c\/strong\u003e module protects backplane bus communication velocity and firmware flash compatibility of connected PLC output cards. By absorbing inductive voltage spikes right at the coil source, the suppressor prevents electromagnetic interference (EMI) noise coupling into EtherNet\/IP deterministic networks or adjacent I\/O modules, preventing false logic triggers and backplane comms dropouts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the installation of the 100-FSV136 varistor module increase the contactor drop-out delay time?\u003c\/p\u003e\n\u003cp\u003eA: Varistor-based suppressors add minimal off-delay to the contactor drop-out time (typically 2-5 ms), maintaining predictable coil release characteristics compared to diode-based suppression circuits.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 100-FSV136 module polarity-sensitive when operating on DC control circuits?\u003c\/p\u003e\n\u003cp\u003eA: No, the metal oxide varistor (MOV) construction provides bidirectional clamping capability, allowing connection across the coil terminals regardless of DC polarity orientation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure main incoming control power is de-energized and locked out prior to physically attaching the module to the contactor coil terminals.\u003c\/li\u003e\n\u003cli\u003eSnap the 100-FSV136 directly onto the front coil terminal slots of the compatible Bulletin 100 contactor or control relay until the retention latch engages.\u003c\/li\u003e\n\u003cli\u003eVerify that terminal connection pins align properly with the coil screws and tighten the terminal screws to the manufacturer-specified torque limits.\u003c\/li\u003e\n\u003cli\u003eKeep control loop wiring short and direct to avoid forming inductive loops that could pick up ambient electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eInspect the module body periodically for discoloration or structural damage resulting from severe power line voltage surges.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":48816878256318,"sku":"100-FSV136","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/Specifications-20_1200x1200_267dc4d4-b9c9-494c-b597-5d623cb76d47.jpg?v=1788161464","url":"https:\/\/www.autooiltech.com\/products\/allen-bradley-100-fsv136-surge-suppressor-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}