{"product_id":"ai810-3bse008516r1-abb-analog-input-8-ch","title":"ABB AI810 3BSE008516R1 Analog Input Module","description":"\u003cp\u003eThe ABB AI810 (3BSE008516R1) is a high-performance 8-channel analog input module engineered for the S800 I\/O distributed control system. This module provides versatile signal processing, supporting both current (0–20 mA, 4–20 mA) and voltage (0–10 V DC, 2–10 V DC) inputs, with each channel independently configurable to meet specific field device requirements.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 single-ended, unipolar analog input channels.\u003c\/li\u003e\n\u003cli\u003e12-bit resolution for precise signal conversion.\u003c\/li\u003e\n\u003cli\u003eIntegrated PTC resistors protect inputs against overvoltage and short-circuit conditions up to 30 V DC.\u003c\/li\u003e\n\u003cli\u003eSupports transparent HART communication for digital data transmission alongside analog values.\u003c\/li\u003e\n\u003cli\u003eElectrically isolated channel group (8 channels isolated from ground) to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eCompatible with a wide range of S800 Module Termination Units (MTUs).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe AI810 is widely utilized in critical industrial environments, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefinery Process Control:\u003c\/strong\u003e Monitoring level, flow, and pressure transmitters in storage and distillation units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurbine Auxiliary Systems:\u003c\/strong\u003e Managing critical data such as lube oil pressure and cooling water temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoiler Control:\u003c\/strong\u003e Providing real-time feedback on fuel feed rates and water levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRenewable Energy:\u003c\/strong\u003e Supporting hydraulic pressure and pitch control management in large-scale power generation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%;\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAI810 (3BSE008516R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–20 mA, 4–20 mA, 0–10 V, 2–10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption (+5V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption (+24V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 V (Rated) \/ 500 V AC (Dielectric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is completely disconnected before inserting or removing the module from the MTU.\u003c\/li\u003e\n\u003cli\u003eThe module must be mounted on a compatible S800 MTU (e.g., TU810, TU812, TU830).\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for analog signals to minimize noise; ensure shields are properly grounded at the designated common point.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation in the control cabinet to prevent heat buildup, as the module dissipates 1.5 W.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to prevent damage to sensitive internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the AI810 compatible with HART?\u003c\/h3\u003e\u003cp\u003eYes, the AI810 is designed to allow transparent transmission of HART communication signals, enabling digital data to pass through alongside the analog process values.\u003c\/p\u003e\u003ch3\u003eWhich MTUs can be used with this module?\u003c\/h3\u003e\u003cp\u003eThe AI810 is compatible with various S800 series MTUs, including the TU810, TU812, TU814, TU818, TU830, TU833, TU835, TU838, and TU850.\u003c\/p\u003e\u003ch3\u003eWhat protection is provided for the inputs?\u003c\/h3\u003e\u003cp\u003eEach input channel features internal PTC current-limiting resistors, providing protection against short circuits to the transmitter supply or accidental overvoltage up to 30 V DC.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":48845923156158,"sku":"3BSE008516R1","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_116ab4c1-af6c-404e-9df2-d3a587582c49.jpg?v=1788666699","url":"https:\/\/www.autooiltech.com\/products\/ai810-3bse008516r1-abb-analog-input-8-ch","provider":"AutoOilTech Limited","version":"1.0","type":"link"}