{"product_id":"abb-tb805-3bse008534r1-modulebus-extension-adaptor","title":"ABB TB805 3BSE008534R1 Modulebus Extension Adaptor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTB805\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3BSE008534R1\u003c\/strong\u003e) serves as a specialized Modulebus outlet designed for the ABB S800 I\/O system architecture. It facilitates physical bus extension between separate I\/O clusters, providing a reliable interface for D-sub connectivity. This termination unit is critical for maintaining high-speed signal integrity when distributing I\/O modules across multiple DIN rails or separate enclosures within a DCS environment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eS800 I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTB805\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3BSE008534R1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunctional Category\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModulebus Extension Adaptor \/ Termination Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Hardware\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eD-sub 25-pin, Female\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Compatibility\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModulebus (Internal and Extended)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnectivity Requirement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne unit per\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTK801\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eextension cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAttaches to the right-hand side of the I\/O station\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Compatibility\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePassive (Signal routing only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDegree 2 (IEC 61131-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e22 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e109 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e25 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.046 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDirective 2011\/65\/EU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Insights and Operational Logic\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIn complex automation topologies, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTB805\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3BSE008534R1\u003c\/strong\u003e) functions as the gateway for the Modulebus signal to exit the local rail. By utilizing a female D-sub 25 connector, it pairs specifically with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTK801\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable to bridge data flow to a secondary I\/O cluster. This allows engineers to expand the I\/O count beyond a single DIN rail while treating the remote modules as part of the same logical station. The hardware is designed for low-impedance signal paths to prevent data packet loss during high-speed communication cycles typical of ABB 800xA systems.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46572489736382,"sku":null,"price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/da50b4421b44271c05f796a6699f18fa_05a76ded-ce3d-4a8d-a385-d085dd5631a8.png?v=1775631074","url":"https:\/\/www.autooiltech.com\/products\/abb-tb805-3bse008534r1-modulebus-extension-adaptor","provider":"AutoOilTech Limited","version":"1.0","type":"link"}