{"product_id":"abb-sb510-backup-power-supply-module","title":"ABB SB510 Backup Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB SB510\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSB510\u003c\/strong\u003e Backup Power Supply, operates as a dedicated hardware component for localized voltage regulation, standby battery management, and uninterruptible power distribution within Advant OCS and matching industrial automation network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSB510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Designation\u003c\/td\u003e\n\u003ctd\u003eBackup Power Supply \/ Battery Charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e110 to 230 V AC (Absolute frequency baseline: 47 to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e110 to 230 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Battery Chemistry\u003c\/td\u003e\n\u003ctd\u003eNickel-Cadmium (NiCd)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Circuit Output Nominal\u003c\/td\u003e\n\u003ctd\u003eDesigned to charge a 12 V, 4 Ah NiCd battery bank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Width\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Height\u003c\/td\u003e\n\u003ctd\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Depth \/ Length\u003c\/td\u003e\n\u003ctd\u003e291 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e0.98 kg (2.16 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive Onboard Battery Cells\u003c\/td\u003e\n\u003ctd\u003e0 (External battery cell connection required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU (RoHS Compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Classification\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No external dimension greater than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCIP Identifier Record\u003c\/td\u003e\n\u003ctd\u003e8a71de04-baf4-4395-9f39-8c98dd9bd6c1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Code (HS Code)\u003c\/td\u003e\n\u003ctd\u003e85044083 (Static Converters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C standard cabinet ambient thresholds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Driver Integration\u003c\/h3\u003e\n\u003cp\u003eThe backup power supply features wide-range input rectification circuitry that accepts either AC or DC main feeder lines, filtering out raw input transients to maintain clean internal DC rails. It manages an external 12 V NiCd battery cell arrangement, using an optimized float-charging curve that prevents thermal degradation while ensuring immediate backup availability. Internal hardware monitoring registers check supply continuity and battery health flags constantly, passing status metrics to higher-level automation nodes via fieldbus heads connected across Profinet or EtherNet\/IP deterministic networks. This architecture isolates the runtime control loops from grid disruptions, optimizing backplane bus communication velocity baselines and ensuring uninterrupted connection tracking during live I\/O density scaling routines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the SB510 module be used with standard Sealed Lead-Acid (SLA) or Lithium-Ion batteries?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal charging loop and voltage regulation profiles of the SB510 are specifically calibrated for the charge\/discharge traits of a 12 V, 4 Ah Nickel-Cadmium (NiCd) battery configuration. Connecting other battery chemistries can lead to improper charging states or hardware damage.\u003c\/p\u003e\n\u003cp\u003eQ: What happens to the automation rack data if the primary 110-230 V AC input source drops out completely?\u003c\/p\u003e\n\u003cp\u003eA: Upon a line voltage drop, the SB510 switches instantly to the connected 12 V NiCd battery loop via internal solid-state diode coupling. This transition occurs without voltage dips or processing latency, maintaining continuous power to the backplane memory and communication chips.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":47600450404542,"sku":"SB510","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-03_10-45-21_7b64ad92-2115-4e93-bf8b-c538bcc2af45.png?v=1780458053","url":"https:\/\/www.autooiltech.com\/products\/abb-sb510-backup-power-supply-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}