{"product_id":"abb-nktl01-3-prefabricated-coaxial-cable","title":"ABB NKTL01-3 Prefabricated Coaxial Cable","description":"\u003cp\u003eThe \u003cstrong\u003eABB NKTL01-3\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNKTL01-3\u003c\/strong\u003e Prefabricated Cable, operates as a dedicated hardware component for connecting NKCL coaxial cables to NTCL termination modules within industrial control and communication networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNKTL01-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e~0.45 kg reference mass (0 kg net recorded commercially)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e157.48 mm x 236.22 mm x 45.72 mm (packaged envelope)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Diameter\u003c\/td\u003e\n\u003ctd\u003e0.04572 mm core boundary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrefabricated Coaxial Cable Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Interface\u003c\/td\u003e\n\u003ctd\u003eConnect NKCL coax cable to NTCL termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e854420 (Coaxial cable and other coaxial electric conductors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85442000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCIP Registration\u003c\/td\u003e\n\u003ctd\u003e9a316f88-53dc-4ed3-a51f-2c8e8bba7097 Romania\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drives Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe NKTL01-3 interconnection assembly routes high-frequency serial data streams and clock waveforms designed to track system variables across backplane bus communication velocity Licences. By providing an impedance-matched physical link between the NKCL coax line and the NTCL interface card, the assembly prevents signal attenuation, standing wave reflections, and signal distortion without introducing data conversion loop lag.\u003c\/p\u003e\n\u003cp\u003eThe internal physical communication layers manage parallel telemetry packets over Profinet \/ EtherNet\/IP deterministic networks via the master system backplane to maintain continuous connection tracking across distributed processor segments. The prefabricated connector termination handles strict signal shielding demands, allowing independent I\/O density scaling routines to run across remote node branches without high-frequency electrical noise disrupting adjacent logic gates. This physical execution baseline ensures that communication packets maintain sharp edge transitions while preserving absolute software configuration firmware flash compatibility across the parent ABB control network platforms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What technical fault occurs if the NKTL01-3 cable assembly exceeds its specified physical bend radius limits?\u003c\/p\u003e\n\u003cp\u003eA: Bending the coaxial structure too sharply compresses the dielectric layer separating the center conductor from the outer braided shield. This alteration shifts the localized characteristic impedance, generating high-frequency signal reflections that manifest as CRC packet errors or total node drops in the controller diagnostics log.\u003c\/p\u003e\n\u003cp\u003eQ: Does the replacement of this physical link require any system node address mapping inside the engineering software?\u003c\/p\u003e\n\u003cp\u003eA: No. The NKTL01-3 functions strictly as a physical layer layer-0 transmission path. It carries the underlying data stream transparently, requiring no software reassignment, address binding, or firmware updates during mechanical installation.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":47603461161150,"sku":"NKTL01-3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-04_16-41-13.png?v=1780565753","url":"https:\/\/www.autooiltech.com\/products\/abb-nktl01-3-prefabricated-coaxial-cable","provider":"AutoOilTech Limited","version":"1.0","type":"link"}