{"product_id":"abb-etl600p7lc-1khl015000r0001-motor-protection-relay","title":"ABB ETL600P7LC 1KHL015000R0001 Motor Protection Relay","description":"\u003cp\u003eConfigured for high-speed fault isolation in low-voltage motor control centers, the \u003cstrong\u003eABB ETL600P7LC 1KHL015000R0001\u003c\/strong\u003e (\u003cstrong\u003eETL600P7LC\u003c\/strong\u003e Motor Protection Relay) provides direct physical\/electrical execution. Operating under factory part number \u003cstrong\u003e1KHL015000R0001\u003c\/strong\u003e, this hardware assembly continuously samples line currents up to 63 A and phase voltages to execute real-time trip commands during overload conditions, phase failures, or short-circuit anomalies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eETL600P7LC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1KHL015000R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSwitzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 75 mm x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003eUp to 63 A continuous measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Options\u003c\/td\u003e\n\u003ctd\u003e24 VDC or 110-240 VAC (Variant-dependent logic rail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Vectors\u003c\/td\u003e\n\u003ctd\u003eOverload, Phase Failure, Short Circuit, Thermal Overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated LED status array \/ LCD diagnostic display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Options\u003c\/td\u003e\n\u003ctd\u003eOptional Modbus, RS485, or Ethernet communication link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Formats\u003c\/td\u003e\n\u003ctd\u003eStandard 35 mm DIN rail or surface panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drives Deterministic Communication Networks\u003c\/h3\u003e\n\u003cp\u003eThe ETL600P7LC coordinates complex thermal tracking registers and safety interlock matrices directly over its native physical interfaces. To pass critical trip notifications and real-time current metrics to central processing hubs without message collision or data latency, the optional communication board uses high-speed industrial protocols to optimize backplane bus communication velocity. This synchronous reporting architecture avoids packet drops during large induction motor starting spikes, supporting flexible multi-motor monitoring arrays and high-density I\/O density scaling options across localized MCC cubicles. Because the safety protection loop runs on independent internal logic clocks, the relay maintains strict firmware flash compatibility with upstream automation platforms, allowing remote field technicians to modify time-current curves and update network profiles without causing signal transit noise or delaying core safety trip execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the chosen mounting configuration alter the thermal threshold of the 0.5 kg enclosure?\u003c\/p\u003e\n\u003cp\u003eA: The 100 mm x 75 mm x 110 mm housing uses natural airflow across its outer surfaces to clear internal heat. While the device handles ambient conditions up to +60 deg C on a horizontal DIN rail, dense vertical stacking or tight panel layouts can limit airflow, requiring localized cooling modifications to prevent false thermal overload tripping.\u003c\/p\u003e\n\u003cp\u003eQ: What action does the relay take if communication drops across the optional Modbus or Ethernet interface?\u003c\/p\u003e\n\u003cp\u003eA: The internal protection loop operates independently of external data links. If a network timeout or broken link occurs, the relay continues running its core current and voltage diagnostics locally, using its standalone logic parameters to protect the connected motor while outputting a fault status through the local LED indicators.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":47589350473918,"sku":"ETL600P7LC 1KHL015000R0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-05-22_15-40-08_21d4ee3d-485f-4215-b29c-640da397d81d.png?v=1780042075","url":"https:\/\/www.autooiltech.com\/products\/abb-etl600p7lc-1khl015000r0001-motor-protection-relay","provider":"AutoOilTech Limited","version":"1.0","type":"link"}