{"product_id":"abb-bailey-imcis01-control-i-o-slave-module","title":"ABB Bailey IMCIS01 Control I\/O Slave Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-565\"\u003eThe ABB Bailey\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eIMCIS01\u003c\/strong\u003e\u003cspan class=\"citation-565\"\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile \u003c\/span\u003eControl I\/O Slave Module\u003cspan class=\"citation-565\"\u003e designed for the \u003c\/span\u003eInfi 90\u003cspan class=\"citation-565\"\u003e and \u003c\/span\u003eNet 90\u003cspan class=\"citation-565 citation-end-565\"\u003e distributed control systems (DCS).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-564 citation-end-564\"\u003eIt serves as a multi-functional interface between the master controller (such as an MFP or BRC) and field devices, handling a mix of analog and digital signals on a single card to provide efficient, localized process control.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan class=\"citation-563 citation-end-563\"\u003e\u003cspan\u003e \u003c\/span\u003eIMCIS01 (Alternate: P-IMCIS-01, YIMCIS01)\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput\/Output Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e4 channels (typically 1-5 VDC or 4-20 mA).\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Outputs (AO):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 channels (4-20 mA or 1-5 VDC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Inputs (DI):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 channels (Optically isolated).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Outputs (DO):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 channels (Open collector, optically isolated).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e* +5 VDC at 332 mA\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-562 citation-end-562\"\u003e+15 VDC at 35 mA\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-561 citation-end-561\"\u003e-15 VDC at 30 mA\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e+24 VDC at 50 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12-bit A\/D for inputs; 10-bit D\/A for outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 70°C (32°F to 158°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-560\"\u003e\u003c\/span\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan class=\"citation-560 citation-end-560\"\u003e\u003cspan\u003e \u003c\/span\u003eGalvanic isolation between field signals and logic for enhanced system safety.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Hybrid Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConsolidates multiple signal types on a single module, reducing the number of slots required for simple control loops (e.g., motor-operated valves or small pump stations).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlave Expander Bus Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunicates with the master module via the proprietary parallel I\/O expander bus for high-speed, deterministic data updates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures onboard LEDs to indicate module status (Ready\/Error) and I\/O health, facilitating rapid field troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with redundant master module configurations to ensure process stability in mission-critical applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePart of the \"Infi 90 Open\" strategy, allowing it to work seamlessly with older Net 90 hardware or modern Symphony Plus Harmony racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-Ready Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in filtering and surge protection help mitigate the effects of industrial noise and electromagnetic interference (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46442651877566,"sku":"IMCIS01","price":1000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/IMCIS02_2.png?v=1770364498","url":"https:\/\/www.autooiltech.com\/products\/abb-bailey-imcis01-control-i-o-slave-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}