{"product_id":"abb-87ts01e-medium-voltage-switchgear","title":"ABB 87TS01E Medium Voltage Switchgear","description":"\u003cp\u003eThe \u003cstrong\u003eABB GJR2363200R0001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eABB 87TS01E\u003c\/strong\u003e Gas Insulated Switchgear, operates as a dedicated hardware component for medium-voltage circuit interruption and distribution control within electrical grid networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGJR2363200R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany \/ Switzerland (Standard factory matrix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.50kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e600 mm (L) x 300 mm (W) x 1500 mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRegulated by auxiliary tripping and spring charging circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 36 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e1250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Withstand Current\u003c\/td\u003e\n\u003ctd\u003e25 kA for 3 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Medium\u003c\/td\u003e\n\u003ctd\u003eSF6 (Sulfur Hexafluoride) gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eFloor Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe integration of the switchgear control architecture involves the transmission of interlocking and monitoring signals over high-velocity serial and parallel networks. Field telemetry paths and sensor arrays route critical status bits directly to sub-modules, which scale high I\/O density points smoothly across the control backplane. System protection triggers require strict firmware flash compatibility matching across the connected protection relays to ensure deterministic circuit interruption speeds during short-circuit faults without signal latency or framing dropouts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the servicing procedures for the SF6 gas insulation system under continuous operation?\u003c\/p\u003e\n\u003cp\u003eA: The SF6 gas insulation system is sealed within an IP67 enclosure to prevent leaking. Gas density must be verified using the integrated mechanical manometer or digital pressure transducers. Replenishment or evacuation processes must be handled utilizing specialized gas carts under complete circuit lockout.\u003c\/p\u003e\n\u003cp\u003eQ: Can this unit handle high-vibration applications or ambient washdowns?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The IP67 rating protects the internal mechanical switching links and primary busbars from dust and high moisture environments. However, the external auxiliary wiring terminal blocks must be mounted inside an appropriately sealed, vibration-isolated marshaling enclosure.\u003c\/p\u003e\n\u003cp\u003eQ: What defines the physical limit of the short-circuit withstand duration?\u003c\/p\u003e\n\u003cp\u003eA: The switchgear is mechanically and thermally rated to withstand a peak short-circuit thermal impulse load of 25 kA for a maximum duration of 3 seconds. Protection relay coordination parameters must be programmed to trip the circuit breaker within this envelope to prevent busbar deformation.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":47603465617598,"sku":"87TS01E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-04_17-51-40_779670a5-5900-4bf2-bd05-cc93920f0ad7.png?v=1780566878","url":"https:\/\/www.autooiltech.com\/products\/abb-87ts01e-medium-voltage-switchgear","provider":"AutoOilTech Limited","version":"1.0","type":"link"}