{"product_id":"abb-560psr00-1kgt026500r0001-power-supply","title":"ABB 560PSR00 1KGT026500R0001 Power Supply","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e560PSR00 R0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Product ID:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1KGT026500R0001\u003c\/strong\u003e) is a high-efficiency subrack power supply module designed for the RTU560 remote terminal system. It converts wide-range 24–60 VDC inputs into stable, low-ripple 5 VDC and 24 VDC outputs. Supporting parallel redundancy, it ensures continuous runtime for critical substation automation and utility telemetry arrays.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e560PSR00 R0001\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct ID Code\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1KGT026500R0001\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Classification\u003c\/strong\u003e: Subrack Redundant Power Supply Unit (PSU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Series Compatibility\u003c\/strong\u003e: RTU560 Remote Terminal Unit Ecosystem\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Input Range\u003c\/strong\u003e: 24 to 60 V DC wide-tolerance window\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Channel One\u003c\/strong\u003e: 5 V DC stabilized regulated voltage at 5.5 A max load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Channel Two\u003c\/strong\u003e: 24 V DC stabilized regulated voltage at 0.7 A max load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Combined Wattage\u003c\/strong\u003e: 44.3 W total continuous power rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Conversion Efficiency\u003c\/strong\u003e: Approximately 85% energy utilization index\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Residual Ripple\u003c\/strong\u003e: Less than or equal to 30 mV (5 VDC loop), less than or equal to 80 mV (24 VDC loop)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAvailability Architecture\u003c\/strong\u003e: Parallel active redundancy configuration capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting Layout\u003c\/strong\u003e: Plug-in chassis module for standard RTU560 subrack channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Housing Footprint\u003c\/strong\u003e: 257 mm x 138 mm x 175 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e: Approximately 0.5 kg (1.10 lbs) without outer shipping container\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSubstation Automation Telemetry\u003c\/strong\u003e: Supplies continuous operational voltages to main processor and communication links within electrical grid distribution nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Grid Monitoring\u003c\/strong\u003e: Powers analog and digital input boards inside remote RTU cabinets to log high-speed switchgear status information.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRenewable Plant Substations\u003c\/strong\u003e: Deploys inside utility interface panels of wind farms and solar arrays to sustain data links with the master control room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePipeline Infrastructure Automation\u003c\/strong\u003e: Drives distributed telemetry hardware blocks along oil and gas distribution channels to ensure continuous pressure measurement updates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":47455677448382,"sku":"560PSR00 1KGT026500R0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/QQ20260423-163901.png?v=1779332428","url":"https:\/\/www.autooiltech.com\/products\/abb-560psr00-1kgt026500r0001-power-supply","provider":"AutoOilTech Limited","version":"1.0","type":"link"}