{"product_id":"aam11b-yokogawa-current-voltage-input-module","title":"AAM11B | Yokogawa | Current\/Voltage Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa AAM11B\u003c\/strong\u003e functions as a Current\/Voltage Input Module designed for acquisition of 0-20 mA DC signals, with transmitter power supply capability, auxiliary voltage output, and software‑defined input range settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e AAM11B\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Yokogawa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e Japan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Not specified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Not specified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e Not specified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e ≤300 mA at 5.0 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal:\u003c\/strong\u003e 0-20 mA DC (transmitter power supported)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Resistance:\u003c\/strong\u003e 250 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAllowable Input Current:\u003c\/strong\u003e ≤40 mA DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTransmitter Power Supply:\u003c\/strong\u003e 25.0 to 25.5 V DC (≤60 mA DC limit)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAuxiliary Voltage Output:\u003c\/strong\u003e 1 to 5 V DC; ≤1 Ω output resistance; ≥10 kΩ load resistance; shared system ground\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSquare Root Extraction:\u003c\/strong\u003e Available by specification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy Rating:\u003c\/strong\u003e Voltage input ±4 mV; Current input ±16 µA; Auxiliary output ±12 mV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEffect of Ambient Change:\u003c\/strong\u003e 10 deg C → Voltage input ±4 mV and ±0.15 % of value; Current input ±32 µA; Auxiliary output ±24 mV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Update Period:\u003c\/strong\u003e 50 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Insulation:\u003c\/strong\u003e Input signals insulated between systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWithstanding Voltage:\u003c\/strong\u003e 1500 V AC\/min\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e I\/O Module Nest\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e M4 screw terminal connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Settings:\u003c\/strong\u003e Configurable via software\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe AAM11B supports integration with \u003cstrong\u003e4-20 mA HART loop protocol\u003c\/strong\u003e, enabling deterministic current and voltage signal acquisition. Input signals are insulated between systems with 1500 V AC\/min withstand capability. Auxiliary voltage output provides stable reference supply, while square root extraction can be enabled via software for flow signal processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ: Can the AAM11B provide power to connected transmitters? A: Yes, the module supplies 25.0 to 25.5 V DC with a current limit of 60 mA DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: How does ambient temperature variation affect measurement accuracy? A: A 10 deg C change results in ±4 mV drift for voltage input, ±32 µA drift for current input, and ±24 mV drift for auxiliary output.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Is square root extraction available for flow measurement signals? A: Yes, square root extraction can be specified via software configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstall the module securely into the I\/O Module Nest.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnect wiring to terminal blocks using M4 screws with proper torque.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintain shield grounding at a single point to prevent ground loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeparate signal wiring from high‑voltage cabling to minimize interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfigure input signal ranges and square root extraction via software before commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":47598783398078,"sku":"AAM11B","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/AAM11_1.jpg?v=1780385349","url":"https:\/\/www.autooiltech.com\/products\/aam11b-yokogawa-current-voltage-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}