{"product_id":"9907-165-woodward-505e-digital-governor-for-steam-turbines","title":"9907-165 | Woodward | 505E Digital Governor for Steam Turbines","description":"\u003ch3\u003e\n\u003cspan\u003eProduct \u003c\/span\u003e\u003cspan\u003eDescription\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eWoodward 9907-165\u003c\/strong\u003e is part of the 505E series of digital governors, designed for precise control of industrial steam turbines with controlled extraction and\/or admission pressure regulation. Built on a 32‑bit microprocessor platform, it delivers high‑performance digital control, advanced diagnostics, and flexible configuration for demanding turbine applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003eKey \u003c\/span\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Woodward\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 9907-165\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e 505E Digital Governor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, cUL\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 14 in (L) × 11 in (H) × 4 in (D)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Type:\u003c\/strong\u003e NEMA 4 (industrial protection)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 18–32 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKeypad\/Display:\u003c\/strong\u003e 30 analog keys, 2 rows × 12 characters resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e –13 °C to +65 °C (–13 °F to +149 °F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2 actuator outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e8 relay outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6 programmable current outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e Program upload\/download capability for easy configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e Shock protection meets US MIL‑STD‑810C, Method 516.2‑1, Procedure 1B\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e \u0026lt; 10 lbs before shipping\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003eFunctional \u003c\/span\u003e\u003cspan\u003eRole\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides digital control of steam turbines with extraction\/admission pressure regulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrives inlet steam valves via dual actuators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffers programmable outputs for integration with plant systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsures fault‑tolerant operation with rugged industrial design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003eApplication \u003c\/span\u003e\u003cspan\u003eScenarios\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial steam turbines\u003c\/strong\u003e in power generation and utilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSmall turbogenerators\u003c\/strong\u003e requiring precise valve control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTurboexpander models\u003c\/strong\u003e in petrochemical and energy industries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSafety‑critical turbine operations\u003c\/strong\u003e needing CE\/UL certified equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eFAQ\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of turbines is the 9907-165 designed for?\u003c\/strong\u003e A: It is built for industrial steam turbines, turbogenerators, and turboexpanders with extraction\/admission control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How does it control turbine operation?\u003c\/strong\u003e A: By using two actuator outputs to drive inlet steam valves, while monitoring pressure and system parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the unit rugged enough for harsh environments?\u003c\/strong\u003e A: Yes, it features a NEMA 4 enclosure and meets MIL‑STD‑810C shock protection standards.\u003c\/span\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":46377575383230,"sku":"9907-165","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/woodward-9907-162-digital-governor-turbine-control-phinchrricg.png?v=1773284227","url":"https:\/\/www.autooiltech.com\/products\/9907-165-woodward-505e-digital-governor-for-steam-turbines","provider":"AutoOilTech Limited","version":"1.0","type":"link"}