{"product_id":"900b16-0202-honeywell-analog-outputs-module","title":"900B16-0202 | Honeywell | Analog Outputs Module","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Honeywell \u003cstrong\u003e900B16‑0202\u003c\/strong\u003e Analog Output Module provides sixteen isolated current outputs for HC900 systems, delivering precise 0–20 mA analog control with high accuracy and robust diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e: 900B16‑0202\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Analog Outputs 0–20 mA, 16‑Channel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutputs per Module\u003c\/strong\u003e: 16 outputs, isolated in 4 groups of 4 (1–4, 5–8, 9–12, 13–16)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Range\u003c\/strong\u003e: 0 to 21.0 mA, range selectable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLoad Resistance\u003c\/strong\u003e: 750 ohms max\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGalvanic Isolation Group‑to‑Group\u003c\/strong\u003e: 500 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGalvanic Isolation from Logic\u003c\/strong\u003e: 500 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: 0.1% full scale at reference conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModules per Rack\u003c\/strong\u003e: Maximum 2 when powered from internal 24 V backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Current Sensing\u003c\/strong\u003e: \u0026gt; 0.5 mA per output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCalibration Data\u003c\/strong\u003e: Stored in non‑volatile memory; redundant factory calibration; automatic rejection of bad version; individual channel field calibration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Monitoring of factory calibration, field calibration, and configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Verification\u003c\/strong\u003e: Feedback to controller confirming output current flow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eD\/A Resolution\u003c\/strong\u003e: 13+ bits (1 part in 13332)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply Loading\u003c\/strong\u003e: 5 V: 350 mA max \/ 24 V: 700 mA max\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Block\u003c\/strong\u003e: 36‑position Euro‑style (Model 900TCK‑0001)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e: 2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh‑Density Outputs\u003c\/strong\u003e: 16 isolated current outputs for compact analog control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePrecise Current Control\u003c\/strong\u003e: Selectable 0–21 mA range with 0.1% full‑scale accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStrong Isolation\u003c\/strong\u003e: 500 V DC isolation group‑to‑group and from logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAdvanced Calibration\u003c\/strong\u003e: Redundant factory calibration plus field calibration per channel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eComprehensive Diagnostics\u003c\/strong\u003e: Monitors calibration integrity and configuration status\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Verification\u003c\/strong\u003e: Confirms actual current flow to ensure safe operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh‑Resolution D\/A\u003c\/strong\u003e: 13+ bit resolution for smooth analog output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Reliability\u003c\/strong\u003e: Designed for continuous operation in HC900 process environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHow many outputs does the 900B16‑0202 provide\u003c\/strong\u003e: It provides 16 outputs, isolated in 4 groups of 4.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat is the output current range\u003c\/strong\u003e: 0–21 mA, selectable.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDoes it support calibration\u003c\/strong\u003e: Yes, factory and field calibration with automatic bad‑data rejection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat isolation levels are provided\u003c\/strong\u003e: 500 V DC group‑to‑group and 500 V DC from logic.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHow is output verified\u003c\/strong\u003e: Feedback confirms that output current is flowing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47978687824062,"sku":"900B16-0202","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/900A16-0101_3.jpg?v=1782287705","url":"https:\/\/www.autooiltech.com\/products\/900b16-0202-honeywell-analog-outputs-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}