{"product_id":"80190-440-03-r-allen-bradley-smc-flex-interface-pcb-board","title":"80190-440-03-R | Allen-Bradley | SMC-Flex Interface PCB Board","description":"\u003ch1\u003eAllen‑Bradley 80190‑440‑03‑R SMC‑Flex Interface PCB Board\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen‑Bradley 80190‑440‑03‑R\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSMC‑Flex Interface PCB Board\u003c\/strong\u003e, is a dedicated interface card designed for signal handling within Allen‑Bradley SMC‑Flex motor‑control assemblies.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e80190‑440‑03‑R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eAllen‑Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eSMC‑Flex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eInterface PCB Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003ePassive interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe 80190‑440‑03‑R board provides direct electrical interfacing between control logic and the SMC‑Flex power structure. It ensures deterministic communication across the motor‑control frame, handling control‑enable lines, feedback signals, and low‑level coordination between controller and power modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInternal design includes \u003cstrong\u003efuse protection, bus isolation, and stable edge connectors\u003c\/strong\u003e to maintain reliable operation. The board itself contains no programmable firmware; compatibility concerns arise only when paired with updated SMC‑Flex controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCan the 80190‑440‑03‑R be hot‑swapped?\u003c\/strong\u003e  No. Interface boards must be replaced only when the SMC‑Flex assembly is de‑energized.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDoes this board require firmware updates?\u003c\/strong\u003e  No. It contains no flash memory; logic interpretation occurs in the connected controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat signals typically pass through this interface PCB?\u003c\/strong\u003e  Control‑enable lines, status feedback, and coordination signals between controller and power modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure the SMC‑Flex assembly is fully de‑energized before removal or installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintain segregation between control‑signal wiring and high‑energy motor‑power conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify connector seating and avoid excessive force on edge connectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUse proper strain relief to prevent conductor fatigue at terminal points.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLabel all wiring to support maintenance and troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInspect for board‑level contamination or oxidation before energizing the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":48421403525310,"sku":"80190-440-03-R","price":630.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/allen-bradley-80190-480-01-r-drive-control-board-eqyhvhm3azb.png?v=1759044142","url":"https:\/\/www.autooiltech.com\/products\/80190-440-03-r-allen-bradley-smc-flex-interface-pcb-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}