{"product_id":"621-2100-honeywell-digital-output-module","title":"621-2100 Honeywell Digital Output Module","description":"\u003cp\u003eConfigured for discrete state control in PLC-based architectures, the \u003cstrong\u003eHoneywell 621-2100\u003c\/strong\u003e (\u003cstrong\u003e621-2100\u003c\/strong\u003e Digital Output Module) provides direct electrical execution of AC load switching for industrial actuators and signaling devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e621-2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.68 kg (1.50 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PLC rack-mount module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLogic side PLC backplane supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Density\u003c\/td\u003e\n\u003ctd\u003e8 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rating\u003c\/td\u003e\n\u003ctd\u003e115 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Network and Signal Isolation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Voltage Protection Limits:\u003c\/strong\u003e The output circuitry includes snubber networks and transient voltage suppression components designed to manage inductive kickback from AC loads (e.g., solenoids, contactors). These limits protect the module's internal switching elements from over-voltage damage during load de-energization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-rail Mounting Stability:\u003c\/strong\u003e The physical chassis is engineered for rigid mechanical coupling to rack or rail mounting systems. This structural design ensures that the high-density backplane interface remains seated under industrial vibration profiles, preventing intermittent load contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsic Safety (Ex i) Barriers:\u003c\/strong\u003e This module is intended for standard industrial switching and is not intrinsically safe. When interfacing with devices in hazardous locations, external galvanic isolation barriers must be employed to restrict the energy levels to the field circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Conversion Latencies:\u003c\/strong\u003e The module interfaces with the PLC backplane to receive output state commands. The processing of these commands is tied to the PLC deterministic scan cycle, ensuring that output state transitions occur within the system defined timing constraints.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this module compatible with DC load switching?\u003c\/p\u003e\n\u003cp\u003eA: No. The 621-2100 is designed specifically for 115 VAC, 50\/60 Hz applications. Applying DC voltage to the output channels will result in improper switching behavior and potential failure of the output isolation components.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 621-2100 be hot-swapped while the output rack is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. The module does not support hot-swapping. All power to the output rack must be disconnected before the module is removed or installed to prevent potential arcing at the backplane pins or accidental actuation of connected field devices.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the module firmly into the designated PLC rack slot, ensuring the backplane connectors are fully aligned. Engage the module locking mechanism to prevent movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriate wire gauges rated for the 115 VAC circuit capacity. Route output wiring in separate conduits from low-voltage signal lines to prevent induced AC noise from affecting sensitive analog inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Following installation, use a multimeter or load status indicator to verify that the output state corresponds to the command signal issued by the PLC. Ensure the common\/neutral bus is correctly tied to the system AC reference to prevent floating voltage issues.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47959057531070,"sku":"621-2100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-06_11-08-30.png?v=1783316675","url":"https:\/\/www.autooiltech.com\/products\/621-2100-honeywell-digital-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}