{"product_id":"3703e-triconex-isolated-analog-input-module","title":"3703E | Triconex | Isolated Analog Input Module","description":"\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-188\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e3703E\u003c\/strong\u003e\u003cspan class=\"citation-188 citation-end-188\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Isolated Analog Input module specifically designed for the Triconex Triple Modular Redundant (TMR) safety system.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-187 citation-end-187\"\u003eIt provides 16 fully isolated channels, ensuring that field-side electrical interference or ground loops do not compromise the integrity of the safety controller.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"button-label gds-label-m ng-star-inserted\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-186\"\u003e\u003c\/span\u003e\u003cstrong\u003eInput Configuration\u003c\/strong\u003e\u003cspan class=\"citation-186 citation-end-186\"\u003e: 16 Isolated Points\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-185\"\u003e\u003c\/span\u003e\u003cstrong\u003eVoltage Selection\u003c\/strong\u003e\u003cspan class=\"citation-185 citation-end-185\"\u003e: 0-5 VDC or 0-10 VDC (+6% overrange)\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-184\"\u003e\u003c\/span\u003e\u003cstrong\u003eCurrent Measurement\u003c\/strong\u003e\u003cspan class=\"citation-184 citation-end-184\"\u003e: 0-20 mA via external shunt (250 Ω for 5V; 500 Ω for 10V)\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSampling Rate\u003c\/strong\u003e: 50 ms Input Update Rate\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-183\"\u003e\u003c\/span\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003cspan class=\"citation-183 citation-end-183\"\u003e: 12 bits\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-182\"\u003e\u003c\/span\u003e\u003cstrong\u003eSystem Accuracy\u003c\/strong\u003e\u003cspan class=\"citation-182 citation-end-182\"\u003e: \u0026lt; 0.15% of Full Scale Range (FSR) from 0° to 60° C\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-181\"\u003e\u003c\/span\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e\u003cspan class=\"citation-181 citation-end-181\"\u003e: -90 dB @ 60Hz \/ -100 dB @ DC (Minimum)\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-180\"\u003e\u003c\/span\u003e\u003cstrong\u003eCommon Mode Range\u003c\/strong\u003e\u003cspan class=\"citation-180 citation-end-180\"\u003e: ±200V Peak\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-179\"\u003e\u003c\/span\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003cspan class=\"citation-179 citation-end-179\"\u003e: 30 MΩ (DC) minimum, even during Power-Off\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverrange Protection\u003c\/strong\u003e: 150 VDC or 115 VAC continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Filtering\u003c\/strong\u003e: -17 dB @ 60Hz; -23 dB @ 120Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e: 4 Kg (Shipping weight)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommon FAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the isolation in the 3703E protect the system?\u003c\/strong\u003eUnlike standard modules, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3703E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures point-to-point and leg-to-leg isolation, preventing high-voltage transients (up to 200V peak) in the field from damaging the internal Tricon backplane or affecting adjacent channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for 4-20mA loop signals?\u003c\/strong\u003e\u003cspan class=\"citation-178\"\u003eYes, by utilizing a 250 Ω or 500 Ω precision shunt resistor at the termination assembly, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e3703E\u003c\/strong\u003e\u003cspan class=\"citation-178 citation-end-178\"\u003e\u003cspan\u003e \u003c\/span\u003eaccurately converts current signals into the required 0-5V or 0-10V range for processing.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":46394627719358,"sku":"3703E","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/triconex-3706a-thermocouple-analog-input-module-me2ecbxc2id.png?v=1770863308","url":"https:\/\/www.autooiltech.com\/products\/3703e-triconex-isolated-analog-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}