{"product_id":"3604e-triconex-digital-output-modules","title":"3604E | Triconex | Digital Output Modules","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-634\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eTriconex 3604E\u003c\/strong\u003e\u003cspan class=\"citation-634\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance \u003c\/span\u003eDigital Output (DO) Module\u003cspan class=\"citation-634\"\u003e designed for the \u003c\/span\u003eTriple Modular Redundant (TMR)\u003cspan class=\"citation-634 citation-end-634\"\u003e safety system.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-633 citation-end-633\"\u003eThis module is engineered to provide fail-safe control for 16 non-commoned (isolated) output signals, making it ideal for driving critical field devices like solenoid valves and actuators.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-631\"\u003e\u003c\/span\u003e\u003cstrong\u003eOutput Signals:\u003c\/strong\u003e\u003cspan class=\"citation-631\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e16 points\u003cspan class=\"citation-631\"\u003e, which are \u003c\/span\u003enon-commoned\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-630\"\u003e\u003c\/span\u003e\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e\u003cspan class=\"citation-630\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e24 VDC\u003cspan class=\"citation-630\"\u003e, with a high-end operational range of \u003c\/span\u003e22 to 45 VDC\u003cspan class=\"citation-630 citation-end-630\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-629\"\u003e\u003c\/span\u003e\u003cstrong\u003eCurrent Ratings:\u003c\/strong\u003e\u003cspan class=\"citation-629\"\u003e\u003cspan\u003e \u003c\/span\u003eMaximum \u003c\/span\u003e2A per point\u003cspan class=\"citation-629\"\u003e continuous, with a \u003c\/span\u003e10A surge\u003cspan class=\"citation-629 citation-end-629\"\u003e capacity for 10 ms.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-628\"\u003e\u003c\/span\u003e\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e\u003cspan class=\"citation-628\"\u003e\u003cspan\u003e \u003c\/span\u003eTypically \u003c\/span\u003eless than 4V\u003cspan class=\"citation-628 citation-end-628\"\u003e at full load across the internal voter circuitry.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Leakage:\u003c\/strong\u003e\u003cspan class=\"citation-627\"\u003e\u003cspan\u003e \u003c\/span\u003eMaximum of \u003c\/span\u003e2 mA\u003cspan class=\"citation-627 citation-end-627\"\u003e, preventing high-impedance loads from staying energized when \"OFF.\"\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-626\"\u003e\u003c\/span\u003e\u003cstrong\u003ePoint Isolation:\u003c\/strong\u003e\u003cspan class=\"citation-626\"\u003e\u003cspan\u003e \u003c\/span\u003eRated at \u003c\/span\u003e1500 VDC\u003cspan class=\"citation-626 citation-end-626\"\u003e, ensuring protection against electrical cross-talk and transients.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-625\"\u003e\u003c\/span\u003e\u003cstrong\u003eField Protection:\u003c\/strong\u003e\u003cspan class=\"citation-625\"\u003e\u003cspan\u003e \u003c\/span\u003eRequires\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003eone 2.5A fast-acting fuse\u003cspan class=\"citation-625 citation-end-625\"\u003e\u003cspan\u003e \u003c\/span\u003eper output on the Field Termination panel.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-624\"\u003e\u003c\/span\u003e\u003cstrong\u003ePhysical Profile:\u003c\/strong\u003e\u003cspan class=\"citation-624\"\u003e\u003cspan\u003e \u003c\/span\u003eDistinguished by a \u003c\/span\u003eDark Blue\u003cspan class=\"citation-624\"\u003e color code and a shipping weight of \u003c\/span\u003e5 Kg\u003cspan class=\"citation-624 citation-end-624\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuad-Voter Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a fully triplicated output circuit that uses a 2-out-of-3 (2oo3) voting mechanism to verify every command before it reaches the field.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoint-to-Point Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike commoned modules, the non-commoned design provides superior electrical separation, allowing for different power sources or mixed wiring configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Hot-Swap:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports Online Replacement, enabling the module to be swapped out without interrupting the process or compromising the safety of the plant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Self-Tests:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePeriodically executes \"Glitch Tests\" to confirm that all output transistors can open and close properly without affecting the actual state of the field device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-623\"\u003e\u003c\/span\u003e\u003cstrong\u003eFront-Panel Diagnostics:\u003c\/strong\u003e\u003cspan class=\"citation-623\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides real-time status through \u003c\/span\u003ePass, Fault, and Active LEDs\u003cspan class=\"citation-623 citation-end-623\"\u003e, alongside individual status indicators for each of the 16 output channels.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to survive harsh EMI\/RFI environments and features high-grade components for an extended Mean Time Between Failures (MTBF).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":46443395317950,"sku":"3604E","price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/triconex-3805h-analog-output-module-ffbost22ddx_91afa353-6a61-46f9-9b01-77438a717038.png?v=1773892381","url":"https:\/\/www.autooiltech.com\/products\/3604e-triconex-digital-output-modules","provider":"AutoOilTech Limited","version":"1.0","type":"link"}