{"product_id":"3500-05-01-03-05-00-01-bently-nevada-system-rack","title":"3500\/05‑01‑03‑05‑00‑01  | Bently Nevada | System Rack","description":"\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eBently Nevada 3500\/05‑01‑03‑05‑00‑01 \u003c\/strong\u003eSystem Rack is part of the 3500 Machinery Protection System, providing the mechanical and electrical housing for monitoring modules that safeguard critical rotating equipment. This rack is designed to integrate vibration, temperature, speed, and Keyphasor monitoring modules into a unified system, delivering continuous machinery protection and condition monitoring.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e3500\/05‑01‑03‑05‑00‑01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eType:\u003c\/strong\u003e System Rack (housing for 3500 series modules)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e Up to 14 module slots (1 for power supply, 1 for TDI, remainder for monitoring modules)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Works with 3500 series modules (vibration, temperature, Keyphasor®, tachometer, communications)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMounting Options:\u003c\/strong\u003e Panel‑mount or rack‑mount depending on configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Requires 3500\/15 Power Supply (AC or DC options)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Interfaces with 3500\/22M Transient Data Interface (TDI) and communications modules\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eReliability:\u003c\/strong\u003e Built for continuous operation in harsh industrial environments\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSlots:\u003c\/strong\u003e 14 total (including power supply and TDI)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Standard 19‑inch rack width, height ~7U depending on configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 8 kg \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 °C to +60 °C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +85 °C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% non‑condensing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Protection:\u003c\/strong\u003e IP20 standard housing\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCentral housing for\u003cstrong\u003e \u003c\/strong\u003e3500 series machinery protection modules\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003ePower generation (steam\/gas turbines)\u003c\/li\u003e\n\u003cli\u003eOil \u0026amp; gas (compressors, pumps)\u003c\/li\u003e\n\u003cli\u003ePetrochemical and heavy industry rotating equipment monitoring\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegration into DCS\/PLC systems for alarm and trip logic\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eQ: What does the 3500\/05 rack do?\u003c\/strong\u003e \u003cstrong\u003eA:\u003c\/strong\u003e It houses and powers 3500 series monitoring modules for machinery protection.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many modules can be installed?\u003c\/strong\u003e \u003cstrong\u003eA:\u003c\/strong\u003e Up to 14 slots are available, depending on configuration.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is a power supply included?\u003c\/strong\u003e \u003cstrong\u003eA:\u003c\/strong\u003e No, a separate 3500\/15 Power Supply module is required.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eQ: What equipment is it used with?\u003c\/strong\u003e \u003cstrong\u003eA:\u003c\/strong\u003e Turbines, compressors, pumps, motors, and other critical rotating machinery.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45945891258558,"sku":"3500\/05‑01‑03‑05‑00‑01","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/bently-nevada-3500-05-01-01-00-00-00-system-chassis-rack-osi14eyqegh.png?v=1773805900","url":"https:\/\/www.autooiltech.com\/products\/3500-05-01-03-05-00-01-bently-nevada-system-rack","provider":"AutoOilTech Limited","version":"1.0","type":"link"}