{"product_id":"330130-085-00-00-bently-nevada-3300-xl-8-mm-extension-cable","title":"330130-085-00-00 | Bently Nevada | 3300 XL 8 mm Extension Cable","description":"\u003ch2\u003eBently Nevada 330130-085-00-00 3300 XL 8 mm Extension Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330130-085-00-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330130\u003c\/strong\u003e extension cable, serves as the primary coaxial link used to execute probe‑to‑proximitor signal transmission across 3300 XL eddy‑current measurement platforms. This configuration implements an 8.5 m system length, standard cable construction, and no agency‑approval requirements.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e330130-085-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e0.289 kg (calculated from 34 g\/m × 8.5 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e8.5 m cable length (27.9 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003ePassive coaxial component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eStandard 3300 XL extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eStandard coaxial termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy‑Current Scaling and Signal‑Path Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 330130 extension cable maintains calibrated eddy‑current probe scaling, ensuring displacement interpretation remains consistent across 3300 XL systems. Its coaxial geometry preserves the nominal −10 VDC gap‑voltage reference generated by the proximitor, supporting linear response and stable rotor‑dynamic tracking. The 8.5 m factory‑matched length maintains proper impedance without requiring recalibration. Shielding continuity suppresses cross‑talk, reducing induced noise in multi‑probe installations where phase and amplitude accuracy are critical.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the extension cable be replaced while the proximitor remains energized?\u003c\/strong\u003e A: No. Replacement should occur only when the monitoring channel is de‑energized to avoid transient gap‑voltage excursions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does altering cable length affect displacement scaling?\u003c\/strong\u003e A: Yes. System length is factory‑matched. Non‑standard cable lengths change impedance and can shift the scaling curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the cable require firmware compatibility checks?\u003c\/strong\u003e A: No. The extension cable is a passive component and contains no firmware.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eRoute the cable away from high‑current conductors to minimize electromagnetic interference. Maintain gentle bend radii to preserve coaxial impedance. Bond shielding at the proximitor end only to prevent ground‑loop formation. Verify connector seating to ensure stable signal transmission. Apply strain relief to prevent micro‑motion that may introduce noise into rotor‑dynamic measurements.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48184159535294,"sku":"330130-085-00-00","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/aec52dcfa81cb2a1ad8a3a7bc2de32de_0474ffbe-d626-4eab-b083-82b33739267d.png?v=1776063817","url":"https:\/\/www.autooiltech.com\/products\/330130-085-00-00-bently-nevada-3300-xl-8-mm-extension-cable","provider":"AutoOilTech Limited","version":"1.0","type":"link"}